BANDIT CONTROLS - CE
Bandit
83
15
245840062970 8Oct2018
Electric Feed Assist
Electric Winch with Feed Assist
There is a switch on the winch that sends a 12V signal to enable the winch valve. The Winch Out Switch
indicates to the control system whether the winch is stowed or deployed and also provides voltage directly to
the winch control switches on the joystick. The status of the Winch Out Switch is displayed on Maint1 as
shown above right.
Electric Feed Assist is designed to operate both Feed and Winch functions at the same time but only for short
durations. When the Winch is deployed away from its stow point and the Winch valve is enabled, moving the
Feed Assist joystick to the right will also enable Feed Fwd for approx 1/2 sec, then it will timeout and stop; this
can be repeated.
In order for the Feed Assist timer to work and allow oil during Feed Assist, the controller must see :
- a 4.99V (12V) signal from the Winch Out Switch
- a 10,000 (>500) signal from Fd Assist Switch
When the operator is finished with winch operations, the winch rope must be stowed properly to tighten
down on the Stow Bar. The Winch Out Switch will remove voltage from the Winch control switches on the
joystick and also indicate that the winch is no longer deployed and normal chipper functions can resume feed
fwd, etc.
The Yoke/Lift is disabled while winch is deployed. Except, Yoke/Lift can momentarily operate with Feed-
Assist-Fwd. Yoke/Lift is fully enabled again once the winch is properly stowed tight on the stow bar.
If the Feed Assist Switch is disconnected a 10,000 (>500) signal will be sent to the control system. The Feed
Assist will then time out and prevent Feeding until the switch is reconnected to ground for 0 (<500) signal.
Winch In/Out,
Winch Feed FWD/REV
Содержание Intimidator 12XP
Страница 2: ......
Страница 18: ......
Страница 80: ...66 3 19 Replacement Parts Model 12XP CE HYDRAULIC FUEL TANK ASSEMBLY 4 5 10 6 7 9 8 7 11 3 2 2 1...
Страница 82: ...68 3 19 Service Record Model 12XP CE SERVICE RECORD DATE DESCRIPTION AMOUNT...
Страница 106: ...Bandit Controls CE 3 19 92 24 245840062970 8Oct2018 Program Notes Thr dn btn overrides thr up input...
Страница 108: ...Bandit Controls CE 3 19 94 SERVICE RECORD DATE DESCRIPTION AMOUNT...