2. Reading 30 words at R/W head 1, start address 10, problem during reading
Note
If a problem occurs, the AF bit is set with the corresponding status number instead of
the AE bit. Setting the AF bit cancels the job and declares it as finished.
Control
Identification system
1.
Process output buffer
(note sequence):
2.
Process input buffer:
(note sequence):
If problem occurs immediately!
0000
hex
Command designator
0001
hex
RXm1
Set AA bit
0001
hex
Start address 000A
hex
0000
hex
Enter status number
0002
hex
Number of words 001E
hex
RXm3
Set AF bit
RYm0
Reset AV bit
3.
Process input buffer:
4.
0000
hex
…
000F
hex
Copy status number
RXm1
Reset AA bit
RYm6
Reset AV bit
RXm3
Reset AF bit
7
Device Function