BIS V-6111 CC-Link
Processor unit
40
english
ISO 15693
Read times Data carrier with 16 bytes per block
Data carrier detection
≤ 20 ms
Read bytes 0 to 15
≤ 25 ms
for each additional start of a 16-byte block
≤ 10 ms
Write times Data carrier with 16 bytes per block
FRAM
(BIS M-1_ _-02/20)
EEPROM
(BIS M-1_ _-03/07/08)
Data carrier detection
≤ 20 ms
≤ 20 ms
Write bytes 0 to 15
≤ 60 ms
≤ 80 ms
for each additional start of a 16-byte block
≤ 25 ms
≤ 80 ms
High speed*
Read times Data carrier with 64 bytes per block
Data carrier detection
≤ 20 ms
Read bytes 0 to 63
≤ 14 ms
for each additional start of a 64-byte block
≤ 6 ms
Write times Data carrier with 64 bytes per block
Data carrier detection
≤ 20 ms
Write bytes 0 to 63
≤ 30 ms
for each additional start of a 64-byte block
≤ 15 ms
*These times apply only to the combination of read/write head BIS VM-3_ _-
4
01-S4 with BIS M-1_ _-
11
/A,
BIS M-1_ _-
13
/A, BIS M-1_ _-
14
/A , or BIS M-1_ _-
15
/A data carriers.
Read times
Data carrier with 16 bytes per block
BIS L-1_ _
Data carrier detection
≤
110
ms
Read bytes 0 to 15
≤
175
ms
for each additional start of a 16-byte block
≤
40
ms
Data carrier BIS L-2_ _
Data carrier det Read data carrier ≤ 140 ms
Write times
Data carrier with 16 bytes per block
BIS L-1_ _
Data carrier detection
≤
110
ms
Write bytes 0 to 15
≤
285
ms
for each additional start of a 16-byte block
≤
100
ms
Data carrier BIS L-2_ _
Writing not possible
For read/write
heads BIS VL
7