BIS V-6111 CC-Link
Processor unit
34
english
Command designator 0032
hex
: Write constant value to data carrier
Subaddress
Meaning
Function description
0000
hex
Command
designator
0032
hex
: Write constant value to data carrier.
0001
hex
Start address
Start address to be written from.
0002
hex
Number of words
Number of words to be written starting from the start
address.
Data is accepted from the processor unit only after the command has been accepted by the
processor unit and acknowledged.
0000
hex
Data
Value that is to be written to the data carrier.
0001
hex
None
No meaning
Command designator 0051
hex
: Set device parameters
Subaddress
Meaning
Function description
0000
hex
Command
designator
0051
hex
: Set device parameters
0001
hex
Device parameter
Bit 0: Display / Keyboard read-only, if 1
Bit 1: Energy saving function of LEDs active, if 1
Command designator 0052
hex
: Set head parameters
Subaddress
Meaning
Function description
0000
hex
Command
designator
0052
hex
: Set head parameters
0001
hex
Head parameter
If the corresponding bit is set to 1, the function is active:
Bit 0: CRC
Bit 1: Dynamic mode
Bit 2: Output type and serial numbers if Tag-Present
Bit 3: Energy saving function – slow data carrier
detection
Bit 4: Energy saving function – reduced transmitting
power
Bit 5: Energy saving function – shut off LEDs
0002
hex
Data carrier type
1: All data carriers are detected
10: Mifare
11: ISO 15693
20: EM4x02
21: Hltag1
22: HltagS
30: BIS C 32 Byte
31: BIS C 64 Byte
0003
hex
Repeat counter
Bits 0…2 Repeat counter for L-heads.
7
Device Function