BIS V-6111 CC-Link
Processor unit
36
english
Command designator 0091
hex
: Copy data between data carriers with 24-bit address
assignment
Subaddress
Meaning
Function description
0000
hex
Command
designator
0091
hex
: Copy data
0001
hex
Source start
address (low word)
Copy the start address of the source data carrier for the
function from which copying is to start.
0002
hex
Source start
address (high word)
Copy the start address of the source data carrier for the
function from which copying is to start.
0003
hex
Target start address
(low word)
Copy the start address of the target data carrier for the
function from which copying is to start.
0004
hex
Target start address
(high word)
Copy the start address of the target data carrier for the
function from which copying is to start.
0005
hex
Number of words
(low word)
Number of words to be copied starting from the source
start address.
0006
hex
Number of words
(high word)
Number of words to be copied starting from the source
start address.
0007
hex
Target R/W head
number
Number of the read/write head that the target data
carrier is in front of.
Command designator 0092
hex
: Initialize CRC_16 data check with 24-bit address assign-
ment
Subaddress
Meaning
Function description
0000
hex
Command
designator
0092
hex
: Initialize CRC_16 data check.
0001
hex
Start address (low
word)
Start address from which the CRC_16 data check is to
be carried out.
0002
hex
Start address (high
word)
Start address from which the CRC_16 data check is to
be carried out.
0003
hex
Number of words
(low word)
Number of words for which a CRC_16 data check is to
be carried out from the start address (low word).
0004
hex
Number of words
(high word)
Number of words for which a CRC_16 data check is to
be carried out from the start address (high word).
Command designator 00B2
hex
: Write constant value to data carrier with 24-bit address
assignment
Subaddress
Meaning
Function description
0000
hex
Command
designator
00B2
hex
: Write to data carrier.
0001
hex
Start address (low
word)
Start address to be written from.
0002
hex
Start address (high
word)
Start address to be written from.
0003
hex
Number of words
(low word)
Number of words to be written.
0004
hex
Number of words
(high word)
Number of words to be written.