www.balluff.com
BIS V-6111 CC-Link
Processor unit
37
english
Bit header
If the IO-Link function is disabled, the bit header from head 1 has the CC-Link point address
RXm0…RXm7. If the IO-Link is enabled, the point address RX(m+4)0…RX(m+4)7 and the
number of points has to be greater than or equal to 96.
Bit No.
Header
0
CP
1
AA
2
AE
3
AF
4
MT
5
TO
6
HF
7
BB
Point address of bit header 1–4
Head 1
Head 2
Head 3
Head 4
IO-Link
disable
RXm0…RXm7
RXm8…RXmF
RX(m+1)0…
RX(m+1)7
RX(m+1)8…
RX(m+1)F
IO-Link
enable
RX(m+4)0…
RX(m+4)7
RX(m+4)8…
RX(m+4)F
RX(m+5)0…
RX(m+5)7
RX(m+5)8…
RX(m+5)F
Assignment and explanation
Subaddress
Bit name
Meaning
Function description
RXm0
CP
Code Present
A data carrier has been detected.
RXm1
AA
Job start
A job was detected and started.
RXm2
AE
Job end
A job was completed without errors.
RXm3
AF
Job error
A job was processed incorrectly or was
canceled.
RXm4
MT
Multiple Tag
More than 1 data carrier is in the R/W
head's field.
RXm5
TO
Toggle bit out
Read: Additional data is being provided by
the identification system.
Write: Identification system can accept
additional data.
RXm6
HF
Head error
Cable break to the R/W head.
RXm7
BB
Ready
After powering up or after a reset via the
GR bit (of the output buffer, see page 31)
the BB bit indicates that the corresponding
channel is ready.
Input buffer
7
Device Function
Содержание BIS V-6111 series
Страница 1: ...BIS V 6111 CC Link Technical Description User s Guide english...
Страница 2: ...www balluff com...