BIS V-6111 CC-Link
Processor unit
46
english
3. Reading 30 words at R/W head 1, start address 10, problem during reading
Note
If a problem occurs after transmission of the data has started, the AF bit is provided
instead of the AE bit together with a corresponding status number. The AF status
message is dominant. Which data is incorrect cannot be specified. Setting the AF bit
cancels the job and declares it as finished.
Control
Identification system
1.
Process output buffer
(note sequence):
2.
Process input buffer
(note sequence):
0000
hex
Command designator
0001
hex
RXm1
Set AA bit
0001
hex
Start address 000A
hex
0000
hex
…
000F
hex
Enter first 16 words
0002
hex
Number of words 001E
hex
RXm5
Invert TO bit
RYm0
Reset AV bit
3.
Process input buffer:
4.
Process input buffer:
If a problem has occurred!
0000
hex
…
000F
hex
Copy first 16 words
0000
hex
Enter status number
RYm6
Invert TI bit
RXm3
Set AF bit
5.
Process input buffer:
6.
0000
hex
Copy status number
RXm1
Reset AA bit
RYm0
Reset AV bit
RXm3
Reset AF bit
7
Device Function