H. Lifting Lever
This is an external, physical means of allowing the pilot
valve to relieve dome pressure so that the main valve
can open.
I. Manual, Electrical, or Pneumatic
Blowdown Valve
(Figures 74 & 75)
An optional manual blowdown valve is available for
relieving the pilot operated safety relief valve. Consult
factory for applications requiring a pneumatic or
electrical solenoid blowdown valve which may be
connected to a distant location, such as an operator
station, for remote actuation. The blowdown valve
is ported directly to the main dome area, so that the
media in the dome is vented when the blowdown valve
is actuated, thus allowing the main valve to open.
Figure 74: Manual Blowdown Valve
Figure 75: Electrical Blowdown Valve
XXII. 2900 Pilot Valve Options (Contd.)
80 | BHGE
© 2018 Baker Hughes, a GE company. All Rights Reserved.