76
THE ALDE HEA
TING S
Y
STEM
> Check the 12V cable is plugged into the
boiler. Check the cable is plugged into the
Alde control panel.
The boiler will not ignite on gas, but no error
message
> The system may not need to use gas heating
if also using electric heating.
> The fluids in the boiler may already be at
operating temperature.
The boiler will not heat on 230V electric
> Check the circuit breaker and any 230V
fuses.
> Check that any 230V fused spurs are on
(they will often have an LED indicator and
230V fuse).
> Check the 230V supply (also indicated on the
Standby Screen).
> The fluids in the boiler may already be at
operating temperature.
No hot water
> Check that Hot Water Ignore is not activated
on the Alde control panel.
> Check that Continuous pumping is not
activated on the Alde control panel.
> Check for other conflicting settings on the
Alde control panel or restore factory defaults.
> Check the water pump and cold water supply
to the boiler.
No central heating
> Bleed the system of air.
> Check the fluid level in the expansion tank.
> Check that the circulation pump is
responding.
> Check that hot water boost is not activated
on the Alde control panel.
> If electric heating is not being used, set it to
“Off” on the Alde control panel.
> Use gas and electric heating for best
performance.
> Check that top and bottom vents in the
furniture are not obstructed.
> Check the condition of the heat transfer fluid.
> Most vehicles will reach a comfortable
temperature within 40 mins, in non-extreme
conditions.
Set up Antimicrobial Function
To actively kill Legionella, setup the
Antimicrobial function. At 2:00 every night, the
hot water will be heated to over 65 °C for 30
mins. This further reduces the risk of Legionella.
1. Press Tool button to access the Settings
Menu (bottom right in Main Menu).
2. Press Clock button, set the time and day.
Press Return.
3. Press down arrow, until Antimicrobial
button is displayed.
4. Press Antimicrobial button to proceed.
>
Settings
To learn more about the Settings Menu and
programmable features of your Alde heating
system, the complete operating instructions
can be downloaded from www.alde.co.uk
To store programmable features between sites
the optional Alde 3020-420 AA battery backup
is required.
Maintenance
The Alde control panel requires no maintenance,
other than cleaning of the screen as needed.
Use a microfibre cloth to clean the touchscreen.
NB: Consider removing the Alde control panel
over winter, if the vehicle is to be kept in storage
and is susceptible to damp.
Troubleshooting
Any error messages will be displayed on the
Standby Screen. Error messages can be cleared
by removing 12V supply to the boiler for 10 secs.
The system is completely dead, the control
panel is blank
> Check the 20 mm T3.15 Amp glass fuse in
the boiler. This is located under the lid of the
black plastic service hatch, in a green plastic
fuse holder.
> Check the 12V supply to the boiler, it should
be above 12V.
Содержание Approach Autograph Series
Страница 1: ...OWNER S MANUAL...
Страница 10: ......
Страница 25: ......
Страница 33: ......
Страница 59: ......
Страница 134: ......
Страница 139: ...137 SURFACE CARE Thermal Healing Of Microscratches Maintenance Instructions Melamine Foam Sponge...
Страница 140: ......
Страница 162: ......
Страница 163: ...161 THE FIAMMA AWNING The Fiamma Awning Opening The Fiamma Awning 161 Closing The Fiamma Awning 163 Maintenance 163...
Страница 176: ...SERVICE MANUAL...
Страница 177: ......
Страница 179: ...Motorhome Overview 4...
Страница 187: ...12...
Страница 188: ...13...