47
THE G
A
S S
Y
STEM
Truma Monocontrol Cs Safety Gas
Pressure Regulator
- Autograph
Only
The Autograph range is fitted with a Truma
MonoControl CS safety gas pressure regulator
which can be found inside the gas locker.
Only a high pressure gas hose with integrated
hose rupture protection (HRP) should only be
used to connect the gas cylinder to the gas
pressure regulation system.
The integrated crash sensor complies with the
Heating Equipment Directive 2001-56-EC with
the supplements 2004-78-EC and 2006/119/EC.
The crash sensor enables you to use a liquid
gas heater while driving, providing suitable
precautions against an uncontrolled release
due to an accidental disconnection. In the event
of an accident (with deceleration of 3.5g with
a tolerance of 0.5g acting directly upon the
triggering element) the integrated crash sensor
interrupts the flow of gas.
The gas system is certified for use throughout
Europe. This includes use while the vehicle is
being driven.
It is important that only upright gas cylinders
are used when operating the MonoControl CS
gas pressure regulation system. Gas cylinders
from which gas is extracted in the liquid phase
must not be used, since they would result in
damage to the gas system.
If you suspect a gas leak then immediately turn
off the supply of gas at the yellow isolation
tap located below the regulator in the gas box.
Then turn off the gas valve on the gas cylinders.
When this has been completed the system must
be inspected by a competent person.
Only use gas cylinders that are mounted in their
dedicated storage locker and secured using
the straps provided. Never use gas cylinders
located outside the motorhome gas box.
WARNING: Never replace your
regulator with one that does not
conform to EN12864 Annex D as this
does not comply with EN1949.
WARNING: Never extend the hose; IT
MUST NOT EXCEED 450MM.
WARNING: The pressure regulating
device and hoses must be replaced
with new ones no more than 10 years
after their date of manufacture (8
years if used commercially).
This is the responsibility of the owner.
WARNING: Do not use a regulator
with a different operating pressure.
WARNING: In the case of a
connection on a pressure regulator
or gas appliance which relies upon a
sealing washer to maintain a gas-
tight joint, it is essential to check
that the washer is present and that it
is correctly positioned prior to
making the connection. Where the
connection relies on a metal to metal
seating or bull nose connection to
obtain a gas-tight joint it is essential
that the mating surfaces are clean
and undamaged. In no case should a
damaged valve or connection be
used.
Содержание Approach Autograph Series
Страница 1: ...OWNER S MANUAL...
Страница 10: ......
Страница 25: ......
Страница 33: ......
Страница 59: ......
Страница 134: ......
Страница 139: ...137 SURFACE CARE Thermal Healing Of Microscratches Maintenance Instructions Melamine Foam Sponge...
Страница 140: ......
Страница 162: ......
Страница 163: ...161 THE FIAMMA AWNING The Fiamma Awning Opening The Fiamma Awning 161 Closing The Fiamma Awning 163 Maintenance 163...
Страница 176: ...SERVICE MANUAL...
Страница 177: ......
Страница 179: ...Motorhome Overview 4...
Страница 187: ...12...
Страница 188: ...13...