
35
Once the entire scale has had the load cell assemblies installed and aligned correctly,
readjust all bumper checking assemblies to within 1/16” - 1/8”.
At this time drill and install all of the anchors for the base plates. Anchors are sug-
gested to be 3/4” X 7” long wedge anchors. A 3/4” X 36” long drill bit can be used for
the holes.
Load cell assembly
LOAD CELL
LEVEL
Содержание Centurion-DT
Страница 10: ......
Страница 11: ......
Страница 18: ...17 steel deck connection plates top view of concrete deck connection plates...
Страница 46: ...45...