32
Replacing the Dummy Load Cell Stands
Once the end and side checking has been adjusted the dummy load cell stands will
need to be removed and replaced with the actual load cells. It is imperative that the
checking has been adjusted to minimize the lateral movement of the weighbridges
when replacing the stands.
Prior to lifting a module / weighbridge place safety blocking under one of the main
weighbridge structural beams with approximately 1/2” gap between the block and
bottom of the beam. This will stop the module from falling to the foundation in the case
of a stand or load cell falling over.
Starting with a load cell dummy stand in the 4-cell module, use a hydraulic jack to lift
the weighbridge in a location close to the stand being removed. Place the jack under
the outermost beam for the lifting location.
Note that on concrete deck scales that have already been poured, it is recommended
to use two hydraulic jacks placed on opposite sides of the module to lift the module in
a level position. Lifting the module unevenly, mid-section or between load cell locations
will cause cracks in the concrete.
Wood safety blocking under weighbridge modules