25
Adjust the 7/8” X 3” bolts that run lengthwise with the scale so that the distance
between the end module plates is 9-3/4”. This measurement should be taken on both
side of the modules to ensure that the cover plates will fit between the modules properly.
As a reference, you need approximately 10-3/4” to 10-7/8” opening between the
modules’ deck plates in order for the cover plate to fit correctly. Always verify the
correct fitment of cover plates before permanently lagging the scale to foundation.
Side View of Steel Deck Module Connection
*Top View of Module Connection
*
Concrete
deck
scales
may
have
slightly
larger
cover
plate
gap
than
this
Adjust the 7/8” X 3” bolts that run the width of the scale so that the edges of the
connecting modules are aligned.
Once the modules have been aligned correctly with each other, tighten the two 7/8” X 5”
bolts to secure the two modules. Torque to a minimum 175 ft lbs.