22
Take a measurement from the outside edge to the end wall on both sides of the
module end plate to ensure that the module is parallel with the end wall. The
measurements should be within 1/8” of each other. If they are not, lift and adjust the
module to achieve squareness.
The end modules are shipped from the factory with the end bumpers and 3/8” thick
backing plates installed. If additional bumper thickness is needed, additional 1/4” and
1/8” bumper shims are shipped loose and can be installed behind the poly block
bumpers.
Final adjustments to the bumpers can be made once all of the modules have been
installed and connected to one another.
TAKE MEASUREMENT
ON BOTH SIDES
OF MODULE
CORRECT
WRONG
LOAD CELL / DUMMY STAND ALIGNMENT
END WALL APPROACH
Содержание Centurion-DT