13
It is recommended to layout all foundation base plates prior to permanently anchoring
to the foundation.
Set the foundation plates in place. Do not secure the plates to the foundation at this
time.
Ensure that the foundation base plates are all level with each other. Shim plates for
use on the top of the foundation base plates are included.
Shim plates are 1/8” in thickness and are meant to make up minor differences in
height. The acceptable height tolerance between all base plates is +/- 1/8”. Verify with
a laser level or transit
If the amount of the difference in height between the base plates cannot be made up
with the use of the shim plates alone, use non-shrinking grout under the base plate to
bring them uniform in height and/or level with the other base plates.