16
Module Assembly (continued)
The left and right halves of weighbridge modules will be bolted together through their
respective connection plates. Be sure that the modules being bolted together are
matching pairs and have the same type of load cell support ends.
First insert (2) 1/2”-13 X 2-1/2” long bolts into the smaller holes to help in aligning the
connection plates. The hex nuts can be added and can be hand tightened at this point.
Insert the 7/8”-9 X 3” connection bolt, lock washer and hex nut into each of the larger
holes on the connection plates. Concrete deck Centurions will use (8) large bolts per
connection plate, while the steel deck versions will use (10).
Hand tighten all bolts until all have been inserted, at which time tightened all to a
minimum of 175 ft. lbs.
Содержание Centurion-DT
Страница 10: ......
Страница 11: ......
Страница 18: ...17 steel deck connection plates top view of concrete deck connection plates...
Страница 46: ...45...