2-1
Chapter 2. NAMES AND FUNCTIONS OF PARTS
Display
OK ALM EV1 EV2
Digital
Mass Flow
Controller
L
L/min
SP
PV
RUN
ENT
DISP
ALM lamp:
Lit when an alarm occurs.
EV1 lamp:
Lit when event 1 output is ON.
EV2 lamp:
Lit when event 2 output is ON.
[RUN] key:
Use this key to change the operating mode.
key:
Use this key to decrement the setting value.
Also use it to move to the function setup mode.
[DISP] key:
Use this key to switch the details displayed
on the 7-segment display.
OK lamp:
Lit when the deviation between the flow set value
and instantaneous flow rate is in the allowable range.
Set the allowable range in the parameter setup.
(For details on how to set parameters, see .)
7-segment display:
Displays the instantaneous flow rate,
flow set value, totalized flow, amperage
to the valve and the operating mode.
It also displays parameter setup values, function
setup values and details of alarms.
SP lamp:
Lit when the flow rate
setpoint is displayed.
L lamp
*1
:
Lit when the totalized flow is displayed.
Blinks when the cumulative
flow event occurs.
PV lamp:
Lit when the instantaneous flow
rate is displayed.
L/min lamp
*2
:
Lit when the instantaneous flow rate
or flow set value is displayed.
[ENT] key:
Use this key to fix and store the set value to
memory.
Also use it to reset the cumulative flow and to
reset alarm and move to the function setup mode.
key:
Use this key to increment the setting value.
Additionally, this key is used to change to
the device information display mode.
key:
Use this key to move to a desired digit
when changing setting value. Also use it to
move to the parameter setup mode.
[ ]
[ ]
[ ]
*1 This lamp is used for mL or m
3
instead of L on some models.
*2 This lamp is used for mL/min instead of L/min on some models.
Note
•
Technical terms used in this manual are defined as follows:
•
SP (setpoint):
The flow set value (or flow rate set point)
•
PV (process variable): Instantaneous flow rate (or controlled flow rate)
•
Operating mode:
One of 3 modes (valve fully closed/valve
control/
7-seg-
ment
display
Содержание Micro Flow MQV0005
Страница 34: ......
Страница 46: ......
Страница 66: ......
Страница 71: ...7 1 Chapter 7 SPECIFICATIONS Individual specifications Please go to the next page...
Страница 88: ......
Страница 90: ...Specifications are subject to change without notice 10 1st edition Dec 2006 U 4th edition June 2019 V...