Operation using the data setting device
Azbil Corporation
5-10
Model MCB10A
5-5 :
Configuration of OPERATOR'S MODE
Introduction
OPERATOR'S MODE provides the following setting and adjustment items.
For details on functions in the items, see “5-5-1 : Changing setting of damping time
Item
Contents
Screen
DAMPING
Sets a damping time
constant.
20.0 %
* DAMPING
005.0 s
AUTO ZERO
Auto zero adjustment
20.0 %
* AUTO ZERO
READY
CNT-RESET VALUE Sets a built-in counter
reset value.
20.0 %
* CNT-RESET VALUE
0 0 0 4 4 4 4
CNT-RESET READY Resets totalized value to
a built-in counter reset
value.
20.0 %
* CNT-RESET READY
0 0 0 0 0 0 0 0
SPIKE CUT
Sets auto spike cut.
20.0 %
* SPIKE CUT
OFF
AVERAGING
Sets a moving average
function.
20.0 %
* AVERAGING
OFF
DISP SELECT
Selects either % flow
rate, actual flow rate
or totalized value to be
displayed in the main
display.
20.0 %
* DISP SELECT
%
MODE ENTER
ENGINEERING
Enters the
ENGINEERING MODE.
20.0 %
* MODE ENTER
ENGINEERING
MODE ENTER
MAINTENANCE
Enters the
MAINTENANCE MODE.
20.0 %
* MODE ENTER
MAINTENANCE