Configuration and structure of measuring system
Azbil Corporation
1-10
Model MCB10A
Names and description of various parts
The following table describes the various parts of the terminal box.
Name
Description
Transducer cover
•
Jet-proof structure (JIS C0920)
Output signal terminal
•
I.OUT+, -: Analog current output terminals
•
L: Power supply terminal. There are models for 24V DC
and 100V AC. Check referring to the specification.
•
PULSE/STATUS OUT+, -: Open-collector pulse output
and contact output terminals
Grounding terminal
•
Make a single-point grounding (Class D) from the internal
grounding terminal at a place as close to this instrument as
possible.
•
The grounding should be JIS Class D. If not grounded,
malfunctions can result.
Connecting cable
gland for output
signal line conduit
• Wire the signal line by entering it through this.