Safety
Azbil Corporation
iv MagneW
FLEX+/PLUS+
Electromagnetic Flowmeter Detector
CAUTION
Tighten each bolt a little at a time and apply uniform pressure to all the bolts.
If leakage continues after tightening the bolts, make sure that the pipe is not off
center, then continue to tighten each bolt a little at a time.
CAUTION
Using a gasket with too small a diameter can affect the flow velocity distribution,
resulting in inaccurate measurement.
Using a gasket with too large a diameter can cause leakage. Also, any solid
substance in the fluid to be measured could accumulate between the gasket and the
flange, resulting in inaccurate measurement.
CAUTION
The necessary materials and the installation method vary according to the material
of the ring and that of the pipe on which the detector is to be installed. Select the
appropriate method of installation from the following table after confirming the
specifications of the detector to be installed and the conditions of installation.
Improper installation can result in leakage or damage to the pipe flanges.
CAUTION
The use of anything other than the PTFE gaskets provided can result in leakage.
The use of rubber gaskets is not recommended and can cause leakage.
CAUTION
The use of rubber gaskets and a lower fastening torque is not recommended and
can cause insufficient surface pressure between the lining and the grounding ring,
resulting in leakage.
CAUTION
Insufficient grounding can cause output fluctuations, instability of the zero point,
or output drift. Secure single point grounding with a grounding resistance of 100
W
or less is recommended.
Do not ground a welder to the detector to avoid damaging the detector.
Содержание MagneW FLEX+
Страница 8: ...Table of Contents...
Страница 9: ...Table of Contents...
Страница 12: ...List of Figure...
Страница 14: ...List of Table...
Страница 26: ...Introduction Azbil Corporation 1 12 MagneW FLEX PLUS Electromagnetic Flowmeter Detector...
Страница 83: ......
Страница 86: ......
Страница 88: ......