background image

User Guide

P/N 9310 1017 0001F    rev. 2.1 

© 2013 Aviom, Inc.

A-Net Interface Card

Содержание 6416YZ

Страница 1: ...User Guide P N 9310 1017 0001F rev 2 1 2013 Aviom Inc A Net Interface Card...

Страница 2: ...subject to change without notice Notice of Rights All rights reserved No part of this document may be reproduced or transmitted in any form or by any means electronic mechanical photocopy recording o...

Страница 3: ...and the point where they exit the apparatus Only use attachments accessories specified by the manufacturer 11 Use only with the cart stand tripod bracket or table specified by the manufacturer 12 or...

Страница 4: ...sing any audio system at high volume levels can cause permanent damage to your hearing Set your system volume as low as possible Avoid prolonged exposure to excessive sound pressure levels IMPORTANT T...

Страница 5: ...alue of the product Include your name address phone number description of the problem and copy of the original bill of sale with the shipment The Return Authorization number should be written on the o...

Страница 6: ...b site at www aviom com To fulfill warranty requirements your Aviom product should be serviced only at an authorized Aviom service center The Aviom serial number label must appear on the outside of th...

Страница 7: ...nts Mishandling the board may lead to shock fire hazard or equipment failure You must turn off the power of your device before you begin installing the 6416Y2 card Be sure to disconnect the power cabl...

Страница 8: ...Slot 11 Slots versus Channels 11 Slots and Sample Rate 12 Setting Control Master Status 14 Enumeration 15 Adding Pro64 Devices to a Network 15 Control Master and Clock Source 16 Other Clock Sources 1...

Страница 9: ...lot Assignments Front Panel VDC Port 34 MY8 and MY16 Mode Operation 34 DIP Switch Block 9 SW9 35 Network Mode 35 A Net Transmit Settings Manual Mode 35 A Net Receive Settings Manual Mode 36 A Net Tran...

Страница 10: ...Signal Routing to the Console 54 Clock Settings 54 Yamaha Console UI Notes 54 External HA Settings on the LS9 55 Assigning Remote Preamp Channels to the LS9 Faders 56 External HA Settings on the M7CL...

Страница 11: ...udio networking with Pro64 Series products easy to set up and configure in a variety of professional audio situations 6416Y2 A Net Interface Card Features 16 input and 16 output channels Inputs from t...

Страница 12: ...therCon Connector Pro64 Series products feature locking connectors for all network I O The Neutrik EtherCon connector is a dual RJ45 type connector that can receive a standard Category 5e cable or a c...

Страница 13: ...e cleaning solution onto a clean cloth first Then use the dampened cloth to clean the product Never use solvents or abrasive cleaners on the finished surfaces of your Aviom products AC Power The follo...

Страница 14: ...ds m control available AW2400 1 1 O1V96 1 1 O1V96i 1 1 O2R96 4 4 DM1000 2 2 DM2000 6 5 DME24N 2 2 DME64N 4 4 M7CL 32 3 3 M7CL 48 3 3 LS9 16 1 1 LS9 32 2 2 CL1 3 3 CL3 3 3 CL5 3 3 P Note The Pro64 6416...

Страница 15: ...re is no front panel user interface Pro64 Network Manager requires a direct RS 232 serial connection between the computer and the Control Master device on the Pro64 network Normally this is accomplish...

Страница 16: ...e referred to as channels numbered from 1 to 16 in the Yamaha interface P Note The 6416Y2 card is electrostatic sensitive Before handling the card you should briefly touch the host unit s metal casing...

Страница 17: ...6416Y2 card has been configured and is installed in the Yamaha host device all signal routing to from the 6416Y2 A Net Interface Card for processing and or mixing is done from within the Yamaha devic...

Страница 18: ...sed products A Net uses the physical layer of Ethernet but it eliminates all the protocol elements that are designed for computers and IT style networking In audio applications these other layers redu...

Страница 19: ...gnored as it passes through A Net Ports Pro64 I O devices have dual A Net ports labeled A and B Both ports carry a bidirectional A Net stream at all times That is both ports are always transmitting an...

Страница 20: ...sed with A360 A 16II and A 16R Personal Mixers A Net Distributors and the AV P2 and AN 16 o Output Modules Front and rear panels of the ASI A Net Systems Interface The ASI is not compatible with the A...

Страница 21: ...d virtual network audio resources The word channel is ambiguous and may cause confusion when configuring an audio network Channel appears in many contexts including audio mixing consoles mic preamps D...

Страница 22: ...Slot ranges Slot ranges will always have the same maximum number as seen in the sample rate chart At 96kHz for example only Slots 1 through 32 are available the Slot range from 33 to 64 is inactive a...

Страница 23: ...l of the current system wide sample rate Clock Master analog modules only System lock via password on off for supported devices Management of Virtual Data Cable VDC resources Management of stereo link...

Страница 24: ...tion of the interface RS 232 422 STEREO LINK 6416Y2 B A ON CTL CLK AUTO ERR 1 2 3 4 5 6 7 8 9 10 11 12 DIP switch 12 in the down position shown in black is used to set the Control Master status for a...

Страница 25: ...The blue LED is used to indicate network status If valid A Net packets are not received the device will reset and wait until a valid A Net stream is detected During enumeration any conflicts will also...

Страница 26: ...hared throughout the Pro64 network That clock reference can be the Yamaha host s internal clock or an external clock to which the Yamaha host device is synced Changes to the host device s sample rate...

Страница 27: ...if the 6416Y2 card is Control Master and Clock Master for the Pro64 network The Sample Rate section of a rack mounted hardware I O module s front panel interface e g 6416i Input Module includes a grou...

Страница 28: ...Virtual Data Cable assignments Hardware switches such as gain settings on input and output devices and rear panel DIP switches are in the analog domain and are not affected Password protection remain...

Страница 29: ...sing the need to program the card using its DIP switches Most users want the Pro64 Network Manager software to be able to control the settings for the 6416Y2 card setting DIP Switch 9 to the up positi...

Страница 30: ...ires that the host Yamaha device be powered down so that the 6416Y2 card can be removed to have its DIP switch settings changed Refer to the Pro64 Network Manager software s documentation for complete...

Страница 31: ...sion slot in the Yamaha device Always make sure that both thumb screws are firmly attached when using or transporting the Yamaha device with a 6416Y2 installed RS 232 422 Port The nine pin DB9 RS 232...

Страница 32: ...dles are indicated in black Clock and Control DIP Switches Within front panel DIP Switch Block SW7 is a group of four system level DIP switches These control the system lock via password 6416m or AllF...

Страница 33: ...such as gain phantom power and low cut filter directly from the Yamaha user interface Local Code Update The Local Code Update DIP switch is used in conjunction with Pro64 Network Manager s firmware up...

Страница 34: ...CLK LEDs will be lit DIP switch handles are shown in black Clock CLK LED The Clock CLK LED will light yellow when the 6416Y2 card is set to be the Pro64 network s Control Master which automatically s...

Страница 35: ...ons of the various DIP switch blocks on the 6416Y2 Note the locations of the various switches on the diagram that follows the table Also note that Switch Block SW7 is on the front panel of the card fa...

Страница 36: ...7 8 1 2 3 4 5 6 7 8 Transmit Slots fromconsole Transmit Port Control Source Managed Mode Front Panel Receive Slots toconsole Receive Port MY16 MY8 VDC Channel Activation 1 8 Channel Activation 9 16 Re...

Страница 37: ...he down position channels 9 16 are off move a DIP switch to the up position to activate a channel which assigns it to a Slot and makes it available throughout the network These switches are ignored wh...

Страница 38: ...AllFrame devices in the Pro64 network directly from compatible Yamaha consoles ON ON ON ON ON ON SW7 SW8 SW3 SW9 SW4 SW1 SW2 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1...

Страница 39: ...Select Backplane or DB9 connector Selects the source of the Yamaha RS 422 remote control information directly from the console s backplane connector or from the DB9 Remote connector depends on the con...

Страница 40: ...Down 3 Down Up 4 Up Up The m control Channel Slot Control settings are separate from the audio I O setup including A Net Transmit and Receive settings This parameter sets up remote control communicat...

Страница 41: ...Block are numbered 1 8 from left to right ON ON ON ON ON ON SW7 SW8 SW3 SW9 SW4 SW1 SW2 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 This...

Страница 42: ...422 VDC Slot Assignment 1 4 Backplane RS 232 422 VDC Slot Assignment 2 Backplane RS 232 422 VDC Slot Assignment 2 5 Front panel RS 232 422 VDC Slot Assignment 0 Front panel RS 232 422 VDC Slot Assignm...

Страница 43: ...2 422 communication always requires a pair of Virtual Data Cable Slots and that this pair must always be an odd even combination of VDCs The down position is off and the up position is on for each DIP...

Страница 44: ...on The individual DIP switches on block SW8 are numbered 1 10 from left to right ON ON ON ON ON ON SW7 SW8 SW3 SW9 SW4 SW1 SW2 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8...

Страница 45: ...tings controlled by onboard DIP switches Card settings controlled by Pro64 Network Manager software 10 Not Managed Managed Mode The tables that follow show DIP switch settings for transmit receive Net...

Страница 46: ...5 DIP Switch 6 MY8 Mode Slots 1 16 off off Slots 1 8 Slots 17 32 on off Slots 9 16 Slots 33 48 off on Slots 17 24 Slots 49 64 on on Slots 25 32 Note that when running the Yamaha device or Pro64 netwo...

Страница 47: ...ro64 network to operate in Managed Mode which is used when updating firmware or whenever a computer is in control of a Pro64 network using Pro64 Network Manager software The 6416Y2 Device Overview as...

Страница 48: ...es the arrow indicates SW7 on the front of the card shown below DIP switch handles are indicated in black Control Master Remote Control 6416Y2 set as Control Master Choose a Control Master The first s...

Страница 49: ...IP switch 12 up if it was previously used as the Control Master When an external Pro64 I O module is used as the Control Master all Yamaha digital consoles and DME in the system must be set to slave t...

Страница 50: ...l count systems that have clearly defined directional needs such as a 64 x 16 digital snake Remember that Manual Mode systems cannot be connected to a PC and controlled from Pro64 Network Manager soft...

Страница 51: ...e 1 16 17 32 33 48 or 49 64 Use these for audio being sent from the Yamaha device into the Pro64 network Each Slot can be activated individually using SW1 and SW2 see below ON ON ON ON ON ON SW7 SW8 S...

Страница 52: ...he most flexibility activate only the channels Slots you need on each 6416Y2 card leaving network Slot bandwidth available for other Pro64 devices in your network A Pro64 network is capable of having...

Страница 53: ...he console back into the Pro64 network for amp speakers or monitors via Slots 49 64 Only this card will have Slots activated as seen in blocks SW1 and SW2 Card 1 of 3 ON ON ON ON ON ON SW7 SW8 SW3 SW9...

Страница 54: ...7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 49 56 OFF 57 64 OFF Receive 17 32 Transmit 49 64 MY16 The second 6416Y2 card in the 48 x 16 digital snake...

Страница 55: ...er could be set to any other range with no impact on the digital snake s operation Install the Cards Install 6416Y2 card 1 into Yamaha MY expansion slot 1 6416Y2 card 2 into MY expansion slot 2 etc to...

Страница 56: ...n programming a 6416Y2 card manually using its circuit board DIP switches Most of these settings can be ignored and the configuration process greatly simplified by using the free Pro64 Network Manager...

Страница 57: ...a AD8HR an 8 channel device so remote controllable Aviom channels appear to the console as AD8HR devices in units of 8 channels and all text and graphics in the Yamaha user interface will refer to ext...

Страница 58: ...the Pro64 mic preamp pad on or off from the Yamaha control surface Physical Connections Remote control commands between the Yamaha host console and Pro64 remote mic preamps are sent using RS 422 comm...

Страница 59: ...played in four groups of eight channels The LS9 uses MY16 mode and operates at 48kHz Use the following table to determine the number of Pro64 cards that a particular console can support Model MY Slots...

Страница 60: ...m control it cannot be set to the off Control Group as the 6416m and RCI can m control Remote Control Settings on the 6416Y2 On the front panel of the 6416Y2 card set DIP switch 10 to the down positi...

Страница 61: ...ps operate Two choices are available Auto Pad and Manual Pad 7 6416m Mic Input Module Control Group assignment Sets a Control Group 1 4 for the console and 6416Y2 card allows only mic preamps in the s...

Страница 62: ...controllable mic preamps as found in the 6416m and AllFrame there are user selectable options that control how the 24dB pad built into the remote preamps operate Two choices are available Auto Pad an...

Страница 63: ...ro64 network switches 7 8 are down and to transmit audio from the console into channels Slots 33 48 of the Pro64 network switch 5 up switch 6 down A second 6416Y2 card installed in the same console sh...

Страница 64: ...e external clock provided via A Net If a 6416Y2 card is set as the Control Master all Pro64 devices will slave to the console s clock When multiple 6416Y2 cards are installed in a Yamaha host device o...

Страница 65: ...HA screen is displayed Press the Rack 5 8 button to access the LS9 External HA settings External HA Settings on the LS9 The External HA screens on both LS9 series consoles are similar the LS9 16 will...

Страница 66: ...ull size External HA screen that allows all remote controllable parameters to be viewed and edited displayed in groups of eight channels The available virtual racks can be selected by choosing one of...

Страница 67: ...ted 1 The current source of the input to the selected channel LS9 rear panel input jacks MY 2 expansion card etc To use m control with the 6416m the input routing source must be set to Slot Select 3 S...

Страница 68: ...al head amp settings on the M7CL consoles is available from the Virtual Rack window available by pressing the Rack button in the Function Access Area of the console s touchscreen The M7CL touchscreen...

Страница 69: ...open the External HA screen Clicking one of the virtual preamp fields in the External HA tab of the Virtual Rack screen see 2 above will bring up the eight channel External HA screen for the selected...

Страница 70: ...ding the console s rear panel mic line analog inputs or digital audio coming into the console via MY expansion cards To change the assignments first select the overview screen of the channel group you...

Страница 71: ...be changed These Input Patch assignments will save and recall with the M7CL scene memories This close up diagram of the External HA screen shows all editable parameters and routing info Console remot...

Страница 72: ...o gain 48V phantom power and high pass filter HPF made from the Yamaha control surface will be transmitted to the remote mic preamps via the VDC Multiple Yamaha mic preamps can be controlled using thi...

Страница 73: ...Y2 card for example Slots 1 and 2 an odd even pair is required Install the 6416Y2 card in the Yamaha console 4 Connect a DB9 cable from the RS 422 port on the Yamaha console labeled Remote to 5 the RS...

Страница 74: ...ATED DN TTL PORT SETUP 1 8 CTRL MASTER 232 422 10 12 RESERVED 9 11 ON WORD CLOCK IN 75 TERMINATION OUT VIRTUAL DATA CABLE PORTS DIGIDESIGN TASCAM COMPATIBLE YAMAHA COMPATIBLE This diagram shows a DM10...

Страница 75: ...1 will be connected to pin 6 at each end An example of this type of cable is the L Com CSNULL9FF XA where X cable length An example of the type of null modem cable that should be avoided is the L Com...

Страница 76: ...g the connections for a null modem DB9 to DB9 crossover cable can be used when making your own cable Null Modem Cable Wiring for a DB9 to DB9 Crossover Cable Pin Signal Direction Pin 1 1 2 2 3 3 4 4 5...

Страница 77: ...n all Yamaha digital devices A Net 2 EtherCon RJ45 connectors A Net Cable Length 400 feet 120 meters between Pro64 devices Latency 420 s measured from Yamaha backplane to AES3 output through the netwo...

Страница 78: ...68 Specifications ON ON ON ON ON ON 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Dimensions...

Страница 79: ...69 Specifications ON ON ON 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 9 10 11 12...

Страница 80: ...ate settings for the configurations you use frequently Copy this page to plain paper enlarging if necessary and mark DIP switch settings with a pen or marker RS 232 422 STEREO LINK 6416Y2 B A ON CTL C...

Страница 81: ...1 Specifications ON ON ON ON ON ON SW7 SW8 SW3 SW9 SW4 SW1 SW2 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Configuration Project Name Date...

Страница 82: ...lock Diagram RS 232 RS 422 Yamaha backplane Audio Input 1 16 from Yamaha backplane Audio Output 1 16 to Yamaha backplane A Net Virtual Data Cables User Config Settings to from Pro64 network 72 Specifi...

Страница 83: ...mpatible device is added to a Pro64 network Cannot communicate with Pro64 Network Manager Make sure that SW8 DIP switch 1 is down for RS 232 communication Incorrect RS 232 communication settings in bl...

Страница 84: ...ard Configuration window available in the 6416Y2 Device Window s Tools menu When using DIP switch control check that the network Slots to be remote controlled are activated Power down remove the card...

Страница 85: ...ro64 Series 8 A Net Base Slot 35 A Net Cable Length 67 A Net clock 39 A Net Distributor 10 A Net LED 15 21 24 73 A Net Output 21 A Net Port 9 A Net Ports 2 A Net Receive 30 50 52 54 A Net Receive Port...

Страница 86: ...ect multiple cards 7 console compatibility 46 console interface card 10 console remote control enable 50 Control Data 8 62 Control Group 29 30 50 51 Control Master 1 5 13 19 22 38 39 54 74 assigning 1...

Страница 87: ...roup assignment 29 51 H Head Amp HA 47 50 55 58 high pass cutoff 59 High Pass Filter 48 HPF 48 56 59 61 low cut filter 48 Hub MH10 MH10f 15 I Input Patch M7CL 61 Input port MY card 57 Installing Multi...

Страница 88: ...13 23 Control Master 18 Password Protection 18 PC connecting Managed Mode 19 Personal Mixer 1 10 A 16II A 16R 10 23 phantom power 56 61 pinout 21 31 RS 232 422 65 PM1D 40 PM5D 29 61 Port 36 Transmit...

Страница 89: ...range 12 27 41 transmit receive 41 Slot range display 12 Slots 6 11 17 40 Activate 42 43 Assigning 27 per Sample Rate 12 Slots versus Channels 11 software 13 Specifications 67 split 42 static 6 Status...

Страница 90: ...indows 7 5 Windows Vista 5 Windows XP 5 word clock 38 Word Clock 8 16 24 X XLR 11 Y Y1 A Net Interface Card 4 Y1 card Pro16 10 Yamaha 73 74 Clock Source 14 16 expansion port 7 external clock 39 extern...

Страница 91: ...All information will be kept confidential Model Product Serial Number Model Product Serial Number Model Product Serial Number Model Product Serial Number Date Purchased Dealer Name Dealer Location You...

Страница 92: ...1157 Phoenixville Pike Suite 201 West Chester PA 19380 USA Voice 1 610 738 9005 Fax 1 610 738 9950 www Aviom com...