3.5 Batching application
3.5 Batching application
This section applies if your indicator has the Batching application active.
3.5.1 SELECT key default function
In the Batching application you can view the gross, net and tare display values by
repeatedly pressing
SELECT
.
3.5.2 Special key functions
The following keys have an extra function in this application:
F1
F1
acts as a
START
,
STOP
,
RESTART
key on successive presses.
SELECT
Press and hold to access the setpoint editor. Below is the Setpoint editor
menu:
3.5.3 Batching operation
Batching allows the indicator to control up to three motors, timers, augers, gates, etc.
using the three outputs for the purpose of making batches based on weight.
There is one type of batching operation, ingredient filling (up to three ingredients).
Other parameters, that are set in a password protected menu, affect the batching
operation.
out 1
out 2
out 3
Setpnt
Press and hold
SELECT
key
Key in
setpoint
value
Key in
setpoint
value
Key in
setpoint
value
The bargraph will sequentially light up to show from 0 to 100% of the batch weight.