![Avery Weigh-Tronix WPI-135 Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/avery-weigh-tronix/wpi-135/wpi-135_service-manual_3030577030.webp)
30
Calibrate
—CAL
—SPEC
—R-CAL
Calibrate
—INFO
If you press the R-CAL soft key, you can perform a reverse calibration. In
other words, you start with a loaded scale, remove all the weight from the
scale for spanning, then get your zero reading. This may require a container
on a separate scale into which you discharge the material.
1.
Press the R-CAL soft key. . .
Display shows the title
Reverse
Calibration Span and prompts you to
press ENTER.
2.
Press ENTER. . .
The indicator determines span point
#1 and shows
DONE when finished.
The display prompts you to press
any key to continue.
3.
Press any key. . .
Display prompts you to enter a
calibration weight. This is the weight
that is currently on the scale. You
will remove all this weight from the
scale in step 5. This value is used
for spanning the scale. Reference
zero is also acquired at this time.
4.
Key in a calibration weight value
equal to the amount to be
removed from the scale in step
#5 and press the ENTER key. . .
The indicator prompts you:
“REVERSE CALIBRATION ZERO:
Remove load, Press ENTER.”
5.
Empty the scale and press
ENTER. . .
The indicator acquires span point #2
and shows
DONE when finished.
6.
Press any key to return to the
SPEC display.
Press the INFO soft key to access the following soft key group:
VERS
Press this key to view firmware and downloaded file informa-
tion.
VIEW
Press this key to view calibration information.
FACTOR
Press this key to view the calibration data (mV/V and counts) for
the current scale.
Press this key to print out calibration data from the selected
serial port.
Following are detailed instructions for setting these parameters.
You need to remove all
the weight from the scale
in this step.
Содержание WPI-135
Страница 1: ...WPI 135 Indicator Service Manual...
Страница 2: ...2...
Страница 15: ...15 Figure 6 Soft key flowchart for Configure menu...
Страница 38: ...38 17 26 18 27 19 28 20 29 21 30 22 31 23 32 24 33 25...
Страница 41: ...41 WPI 135 ENCLOSURE PARTS AND ASSEMBLY...
Страница 43: ...43 WPI 135 INDICATOR SYSTEM BLOCK DIAGRAM...
Страница 45: ...45 WPI 135 INDICATOR POWER SUPPLY AND SERIAL I O PC BOARD P N 50799 0018...
Страница 49: ...49 WPI 135 INDICATOR I O CABLE IDENTIFICATION PIN OUTS...
Страница 50: ...50 This page intentionally blank...
Страница 52: ...52 WPI 135 2 through 5 SCALES J BOX ASSEMBLY P N 47404 0011 2 SCALES OO29 3 SCALES 0037 4 SCALES 0045 5 SCALES...
Страница 53: ...53 WPI 135 6 through 8 SCALES J BOX ASSEMBLY P N 47405 0010 6 SCALES 0028 7 SCALES 0036 8 SCALES...
Страница 54: ...54 This page left intentionally blank...
Страница 57: ...57 WPI 135 INDICATOR EXTERNAL 16 I O CUTOFF EXPANSION BOARD OPTIONAL P N 49853 0013...
Страница 58: ...58 This page left intentionally blank...
Страница 62: ...62 This page left intentionally blank...
Страница 63: ...63 This page left intentionally blank...
Страница 64: ...64 WPI 135 INDICATOR TO PC KEYBOARD CABLE CONNECTIONS...
Страница 66: ...66 WPI 135 INDICATOR TO TTL KEYBOARD CABLE CONNECTIONS...
Страница 67: ...67 WPI 135 INDICATOR TTL KEYBOARD OUTLINE DRAWINGS...
Страница 68: ...68 WPI 135 ENCLOSURE W STAND OUTLINE DRAWING...
Страница 69: ...69 This page left intentionally blank...
Страница 72: ...72 ProfiBus DP NETWORK INTERFACE MODULE PC BOARD optional DeviceNet NETWORK INTERFACE MODULE PC BOARD OPTIONAL...
Страница 73: ...73 InterBus S NETWORK INTERFACE MODULE PC BOARD OPTIONAL Control Net NETWORK INTERFACE MODULE PC BOARD OPTIONAL...
Страница 74: ...74 This page left intentionally blank...