19
Configuration
—MENU 2
2.
Repeat step 1 for all the display
values (NET, TARE, MIN., MAX.,
ROC, G-TOT, N-TOT, C-TOT,
#-TOT, COUNT, VALUE, PCWT
and ADC. . .
The display returns to the
MENU3 display.
This completes the instructions for all the parameters of Menu1.
These configuration items pertain to a particular scale. If you have enabled
multiple scales, you will be asked which scale you want to configure. Key in
the scale number, press ENTER and continue. If you have enabled only one
scale, continue with the following instructions.
Press the MENU2 soft key to access the following soft key group:
MOTION
Use this key to set the motion detection window size in divisions
and the time window in seconds.
AZT
Use this key to set the AZT window size in divisions and the
time window in seconds.
FILTER
Use this key to set up the Harmonizer filtering to counteract
vibration of the scale.
ZERO
Use this key to set the zero range. This is a percent of capacity
that is allowed to be zeroed when pressing the ZERO key. (0-
100% allowed)
MORE
This accesses the following three soft keys.
RATE
Press this key to configure the display update rate in updates
per second.
ROC
ROC stands for Rate of Change. Press this key to set up your
WPI-135 Indicator to calculate Rate of Change for flow rate, or
weight/time, applications.
RZ/TO
Press this key to configure Print Return to Zero (RZ), Accumula-
tor RZ, Accumulator Timeout, Print Timeout and Zero Timeout.
Following are detailed instructions for setting these parameters.
Use this key to set the motion detection window size in divisions and the
time window in seconds.
For example: If you set divisions to 3 and seconds to 1, if the weight value
does not change more than 3 divisions in one second, the scale or weight is
considered stable.
If you press the MOT'N soft key, follow these instructions:
1.
The current value for the motion
window size, in divisions, is
shown. Press ENTER to accept
this value or key in a new value
and press ENTER. . .
The current time window in seconds
is displayed.
Configuration
—MENU 2
—MOT'N
Содержание WPI-135
Страница 1: ...WPI 135 Indicator Service Manual...
Страница 2: ...2...
Страница 15: ...15 Figure 6 Soft key flowchart for Configure menu...
Страница 38: ...38 17 26 18 27 19 28 20 29 21 30 22 31 23 32 24 33 25...
Страница 41: ...41 WPI 135 ENCLOSURE PARTS AND ASSEMBLY...
Страница 43: ...43 WPI 135 INDICATOR SYSTEM BLOCK DIAGRAM...
Страница 45: ...45 WPI 135 INDICATOR POWER SUPPLY AND SERIAL I O PC BOARD P N 50799 0018...
Страница 49: ...49 WPI 135 INDICATOR I O CABLE IDENTIFICATION PIN OUTS...
Страница 50: ...50 This page intentionally blank...
Страница 52: ...52 WPI 135 2 through 5 SCALES J BOX ASSEMBLY P N 47404 0011 2 SCALES OO29 3 SCALES 0037 4 SCALES 0045 5 SCALES...
Страница 53: ...53 WPI 135 6 through 8 SCALES J BOX ASSEMBLY P N 47405 0010 6 SCALES 0028 7 SCALES 0036 8 SCALES...
Страница 54: ...54 This page left intentionally blank...
Страница 57: ...57 WPI 135 INDICATOR EXTERNAL 16 I O CUTOFF EXPANSION BOARD OPTIONAL P N 49853 0013...
Страница 58: ...58 This page left intentionally blank...
Страница 62: ...62 This page left intentionally blank...
Страница 63: ...63 This page left intentionally blank...
Страница 64: ...64 WPI 135 INDICATOR TO PC KEYBOARD CABLE CONNECTIONS...
Страница 66: ...66 WPI 135 INDICATOR TO TTL KEYBOARD CABLE CONNECTIONS...
Страница 67: ...67 WPI 135 INDICATOR TTL KEYBOARD OUTLINE DRAWINGS...
Страница 68: ...68 WPI 135 ENCLOSURE W STAND OUTLINE DRAWING...
Страница 69: ...69 This page left intentionally blank...
Страница 72: ...72 ProfiBus DP NETWORK INTERFACE MODULE PC BOARD optional DeviceNet NETWORK INTERFACE MODULE PC BOARD OPTIONAL...
Страница 73: ...73 InterBus S NETWORK INTERFACE MODULE PC BOARD OPTIONAL Control Net NETWORK INTERFACE MODULE PC BOARD OPTIONAL...
Страница 74: ...74 This page left intentionally blank...