10
The display mode you pick
may not be the one that
appears on the display. A
display mode called out in the
WT BASIC program overrides
the setting you make through
the front panel.
While in the this menu the
display will show USER-
SELECT in the top left to
remind you of where you are in
the USER menu.
User
— SELECT
—DISP
User
—SELECT
—SCALE
You cannot select a scale
number unless it has been
activated in the SimPoser
program and downloaded to
the WPI-135, or enabled in the
Config menu.
User
— SELECT
User
—SELECT
—TARE
Press the SELECT soft key to access the User—SELECT soft key group:
DISP
Press this key to set the current display mode and active value
SCALE
Press this key to select the scale number you want to use.
TARE
Press this key to enter a known tare weight.
UNIT
Press this key to select the active units of measure.
Following is a detailed description of the four functions listed above.
If you press the DISP soft key, follow these instructions:
1.
The display shows the current
display mode number. Press
ENTER to accept this value or
key in a new number from the list
in Appendix 1, then press
ENTER to accept it.
The display asks for the ACTIVE
VALUE. This is the active display
value.
2.
Choose one of the following
active display values by keying
in 0-13, then press ENTER. . .
The display returns to the USER-
SELECT screen.
0 = Gross
4 = Max
8 = Count Total
12=Piece Weight
1 = Net
5 = Rate of Change
9 = Trans. Total
13=ADC
2 = Tare
6 = Gross Total
10=Count
3 = Min
7 = Net Total
11=Variable
If you press the SCALE soft key the display will ask you to select a scale
number. The currently active scale number is displayed. You can simply
type a new scale number and press the ENTER key. If you have multiple
scales attached to the indicator, this function chooses which scale's weight
is displayed and which one the ZERO and TARE keys will affect.
If you press the TARE soft key the display will show the current tare value
for the active scale. You may key in a new tare weight and press the ENTER
key to override the previous tare weight.
Variable (#11) is a variable
value called out in a WT-
BASIC program. ADC (#13)
stands for Analog to Digital
Counts.
Содержание WPI-135
Страница 1: ...WPI 135 Indicator Service Manual...
Страница 2: ...2...
Страница 15: ...15 Figure 6 Soft key flowchart for Configure menu...
Страница 38: ...38 17 26 18 27 19 28 20 29 21 30 22 31 23 32 24 33 25...
Страница 41: ...41 WPI 135 ENCLOSURE PARTS AND ASSEMBLY...
Страница 43: ...43 WPI 135 INDICATOR SYSTEM BLOCK DIAGRAM...
Страница 45: ...45 WPI 135 INDICATOR POWER SUPPLY AND SERIAL I O PC BOARD P N 50799 0018...
Страница 49: ...49 WPI 135 INDICATOR I O CABLE IDENTIFICATION PIN OUTS...
Страница 50: ...50 This page intentionally blank...
Страница 52: ...52 WPI 135 2 through 5 SCALES J BOX ASSEMBLY P N 47404 0011 2 SCALES OO29 3 SCALES 0037 4 SCALES 0045 5 SCALES...
Страница 53: ...53 WPI 135 6 through 8 SCALES J BOX ASSEMBLY P N 47405 0010 6 SCALES 0028 7 SCALES 0036 8 SCALES...
Страница 54: ...54 This page left intentionally blank...
Страница 57: ...57 WPI 135 INDICATOR EXTERNAL 16 I O CUTOFF EXPANSION BOARD OPTIONAL P N 49853 0013...
Страница 58: ...58 This page left intentionally blank...
Страница 62: ...62 This page left intentionally blank...
Страница 63: ...63 This page left intentionally blank...
Страница 64: ...64 WPI 135 INDICATOR TO PC KEYBOARD CABLE CONNECTIONS...
Страница 66: ...66 WPI 135 INDICATOR TO TTL KEYBOARD CABLE CONNECTIONS...
Страница 67: ...67 WPI 135 INDICATOR TTL KEYBOARD OUTLINE DRAWINGS...
Страница 68: ...68 WPI 135 ENCLOSURE W STAND OUTLINE DRAWING...
Страница 69: ...69 This page left intentionally blank...
Страница 72: ...72 ProfiBus DP NETWORK INTERFACE MODULE PC BOARD optional DeviceNet NETWORK INTERFACE MODULE PC BOARD OPTIONAL...
Страница 73: ...73 InterBus S NETWORK INTERFACE MODULE PC BOARD OPTIONAL Control Net NETWORK INTERFACE MODULE PC BOARD OPTIONAL...
Страница 74: ...74 This page left intentionally blank...