32
Collector-Emitter
Breakdown Voltage
BV
CEO
35 -
-
V
I
C
=0.1mA
Emitter-Collector
Breakdown Voltage
BV
ECO
6 - - V
I
E
=10 A
*Current
Transfer
Ratio CTR 50 - 600 %
Collector Current
I
C
2.5 - 30 mA
I
F
=5mA, V
CE
=5V R
BE
=
Collector-Emitter
Breakdown Voltage
V
CE(sat)
- 0.1 0.2 V
I
F
=20mA, I
C
=1mA
Isolation Resistance
R
ISO
5 x 10
10
10
11
-
DC500V, 40-60% R.H.
Floating Capacitance
C
f
- 0.6
1.0
pF
V=0,
f=1MHz
Cut-off Frequency
f
c
- 80 KHz
V
CE
=5V, I
C
=2mA
R
L
=100, -3dB
Response Time (Rise)
t
r
- 4
18 s
T
rans
fer
Char
ac
ter
is
tic
s
Response Time (Fall)
t
f
- 3
18 s
V
CE
=2V, I
C
=2mA
R
L
=100
I
C
*CTR=
I
F
100%
B. Relay
Output
Specification
Surge strength
:1500 VAC
Nominal power
: 200mw ~ 360mw
Operating power
: 110mw ~ 200mw
C. COIL RATINGS (at 20 oC )
Coil Nominal Voltage
(VDC)
Coil Resistance
10%
Pick-up Voltage
(VDC)
Drop-Out Voltage
(VDC)
Nominal Current
(mA)
5
125
3.75
0.5
40
* Max Continuous Voltage at 20
o
C : 110% of Coil Nominal Voltage
D. CONTACT
RATINGS
Contact Arrangement
1 Form C (SPDT)
max. Switch Power
max. Switch voltage
max. Switch current
125VA 60W
125VAC 30VDC
1A
Contact Resistance
≤
100m
Ω
Resistive Load
1A/125VAC
1A/30VDC
2.15 Connecting POS (Point of Sales)
AVerMedia
®
AVerDVR can be integrated with POS system equipment. Connecting the POS
equipment to AVerMedia
®
AVerDVR system thru RS232 connection, enables you to view,
record and keep track of the items that were sold. You may also select the camera on where to
display all the data.
To connect, locate the RS232 port of the POS equipment and PC. Use an RS232 cable (not
supplied) to make the connection.
RS232 cable
i
For detail of POS installation, please refer to POS Quick Guide.