External alarm input setup:
Select one alarm input from 1,2,3,4, and then choose an alarm type from “Normal Open” and “Normal Close” according to the sensor type.
External alarm input setup includes alarm in handling and alarm in schedule. Alarm in handling includes record camera, PTZ linkage, trigger alarm out, etc.
You can select channels to record for each alarm input.(”
“ means
enable.)Only the selected camera can record, link with PTZ and warn on screen after alarm in.
The linkage order is Alarm in
Trigger camera
Recording, please refer to section 5.4.
PTZ linkage order is Alarm in
Trigger camera
PTZ, PTZ linkage can be setup in “Alarms” and “PTZ Linkage” interfaces.(Fig 5.13)Please make sure the camera has
already linked with alarm in; and preset points, sequences, cruises have been set. The maximum number of preset points is 128, sequence is 16 and cruise is 1.
Note: One alarm in can trigger different channels’ preset point, sequence and cruise, but can only use one of them.
The order of warning on screen is Alarm in
Trigger camera
Warn on screen. This can be setup by select “On Screen Warning” in” Alarm In Handling” menu. If
more than one alarm in or linked with more than one camera, the display images will switch every 10 seconds until the alarm stopping.