5. Click the
Ports
tab.
6. Click
vSwitch
,
7. Click
Edit
.
8. Change the MTU value to 1500 if it is not already configured to that value.
9. Click
OK
.
10. Click the
Ports
tab.
11. Click
Management Network
.
12. Click
Edit
.
13. Change the MTU value to 1500 if it is not already configured to that value.
14. Click
OK
.
15. Repeat steps 1–14 for all hosts in the cluster.
16. Right-click the cluster and attempt to configure High Availability.
Verify the MTU settings of the Avaya Virtual Services Platform 4850GTS switches if you continue to
encounter issues with High Availability configuration. Both devices must be configured to have an
MTU setting of 1950 to ensure proper operation.
1. Connect to the switch.
2. Enter Global Configuration mode.
enable
configure terminal
3. Display the current switch MTU setting.
show sys mtu
4. Change the MTU setting to 1950 if it is not already that value.
sys mtu 1950
5. Confirm the new MTU setting.
show sys mtu
6. Save the new configuration.
save config
7. Repeat steps 1–6 for all applicable Avaya Virtual Services Platform 4850GTS switches.
Related links
Troubleshooting software issues
on page 34
Troubleshooting software issues
October 2017
Troubleshooting the Avaya Pod Fx
™
40