Note:
Because some of the connections are difficult to reach after you install the fan
assembly, Avaya recommends that you connect the following cables first:
a. Left fan in the fan assembly to the Sys Fan 1 connector. Use the short
cable.
b. Center fan in the fan assembly to the Sys Fan 2 connector. Use the short
cable.
c. Right fan in the fan assembly to the Sys Fan 6 connector. (Left side of
board). Route the cable next to DIMM socket 1A (DIMM socket nearest
the processor socket), then across the center of the board, in front of the
processor socket.
d. Center fan in the fan assembly to the Sys Fan 3 connector. (Rear of
board). Route the cable next to DIMM socket 1A (DIMM socket nearest
the processor socket), then to the right side of the processor socket.
e. Left fan in the fan assembly to the Sys Fan 4 connector. (Left side of
board). Route the cable next to DIMM socket 1A (DIMM socket nearest
the processor socket), then to the right side of the processor socket.
12. Lower the right side of the fan assembly into place so that it catches under the hook.
Use caution to ensure no cables are pinched beneath the fan assembly.
13. Set the left side of the fan assembly into place.
14. Tighten the captive screw.
15. Connect the fan cables to the correct fan connectors on the front panel I/O board.
The fan connectors are labeled on the front panel I/O board. Look for FAN SYS
labels.
16. Replace the processor air duct. For instructions, see
17. Replace the server cover. For instructions, see
Removing and replacing the server
18. Take off the ESD strap.
19. Plug in the peripheral devices and Ethernet cables, connect the AC power cords,
and restart the server.
Replacing the MPB96 card
There is one MPB96 card in your server.
Replacing basic chassis components
82 Avaya CallPilot® 600r Server Maintenance and Diagnostics
December 2010
Содержание CallPilot 600r
Страница 1: ...Avaya CallPilot 600r Server Maintenance and Diagnostics 5 0 NN44200 703 01 09 December 2010...
Страница 4: ...4 Avaya CallPilot 600r Server Maintenance and Diagnostics December 2010...
Страница 8: ...8 Avaya CallPilot 600r Server Maintenance and Diagnostics December 2010...
Страница 60: ...Monitoring multimedia hardware 60 Avaya CallPilot 600r Server Maintenance and Diagnostics December 2010...
Страница 72: ...Using Avaya CallPilot system utilities 72 Avaya CallPilot 600r Server Maintenance and Diagnostics December 2010...
Страница 90: ...Replacing basic chassis components 90 Avaya CallPilot 600r Server Maintenance and Diagnostics December 2010...
Страница 102: ...Maintaining the BIOS and system board firmware 102 Avaya CallPilot 600r Server Maintenance and Diagnostics December 2010...
Страница 106: ...106 Avaya CallPilot 600r Server Maintenance and Diagnostics December 2010...