19
Indication
Cause
To do
‘L’ or Low Battery on
Battery is low
Call for service
Four LEDs are blinking
AC power failure
Check the premises fuse
box. Call for service
‘C’ or ‘Tel. Line Fail’
Telephone line test failed
Call for service
Arming fail and
≡
is
displayed
Zone is troubled
Bypass the zone and call
for service
Setting System Features
Changing Codes
The system features eight programmable codes. The first code is the Master Code,
and the remaining seven codes are normal arming and disarming codes.
Do not use ‘0’ as the first digit in a code.
Do not use ‘5’ as first digit in a code number if
Instant Arming
via key 5
was
programmed.
User code shall not start with the same numbers as the installer programming code
(1994).
Do not use same codes or same first digit for different codes. For example if code No.
one is 1234, programming code No. 2 cannot be 1256.
Key Visual Feedback -
Visual ‘feedback’ from the keypad display upon entering of
code. This feature indicates the code entry progress and is most practical when the
keypad buzzer is disabled at Home (Group Bypass) mode, or if selected by
programming. Entry of code by user or installer is confirmed at keypad display.
Display segments will light up clockwise, indicating the sequence of the entered
digits.
Note: After six unsuccessful attempts to enter an invalid code the keypad is
locked.
Delays Delete
4
Delay
Delete
Key 4
#
DELAY DELETE (INSTANT PROTECTION)
Cancels the Entry Delay in zones selected as ‘Delayed’ zones. All zones become
Instant. This feature is optional when Home Mode set and all users are in. Hold-down
‘4’ key, ‘d’ is displayed in confirmation. Instant Protection becomes effective only if
System is armed within 20 seconds following hold-down of ‘4’ key.
5
Chime
Key 5
#
DOOR CHIME
The Door Chime causes the keypad to beep whenever a zone is activated. Door
Chime operates on Chime-programmed zones.
Hold-down key 5 enables and disables the function.
Chime mode is confirmed by ‘c’ displayed on keypad.