14
4. The two Left-Most LEDs blink to indicate that the system is waiting for a new user
code index (user 1 to 8) to be entered
5. Enter the code index (1 for code No. 1; 2 for code No. 2, etc.). User index will be
displayed for 2 seconds, until further digits are entered (eliminate confusing of
index number and code)
6. The two right-most LEDs blink to indicate that the system is waiting for a new
code (1 to 6 digits) to be entered.
If user code is not entered, the code is voided
7. Enter the new code; ‘U’ is displayed for confirmation
8. To quit code setting, hold-down ‘9’
Delete a User Code
1. Hold down key
8
Program
2. While four LEDs are blinking, enter code No. 1 (default 1234)
3. If code is valid, four LEDs will stop blinking, and ‘u’ will be displayed
4. The two left-most LEDs blink to indicate that the system is waiting for a new user
code-index (user 1 to 8) to be entered
5. Enter the code index you want to delete (1 for code No. 1; 2 for code No. 2, etc.)
6. The two right-most LEDs blink to indicate that the system is waiting for a new
code
7. Hold-down ‘9’ key to quit code setting
If user code is not entered, the code is voided. A short beep confirms that the
code has been deleted.
Setting the Follow-Me Telephone Number
The ‘Follow-Me’ feature is applicable only with the dialer; in alarm, Follow-Me
number is dialed first if the communicator (communicator dials to central station) is
not selected.
1. Hold down ‘6’ key twice; wait for the blinking of the three LEDs
2. Enter Telephone Number (maximum 16 digits and 4 pauses), and wait until all
LEDs stop blinking. The ‘Follow-Me’ number is now programmed
3. To delete ‘Follow-Me’ number, access ‘Follow-Me’ programming mode as
described in paragraph 1, just do not enter any number
Sounder
The Keypad sounder enhances the use of system operation and serves as a local alarm
device (requires programming).
In AV-707 (LCD keypad) the user is able to switch the buzzer on and off at each
keypad.