11
AV-701, AV-702 Keypads (LED type)
AV-702 keypad contains identical keys and LED structure.
The Status LED is on
when all the zones are
close.
The Red Armed LED
is on when the system
is armed.
The Shunt LED
indicates that a zone is
bypassed.
Blinking ‘h’ means that the system time is not set; hold-down ’1’ key then ’0’, three
LEDs are blinking, enter time in 24 hours format.
Hold-down functions
To hold-down function accesses, hold down the key for approximately 2 seconds.
Hold down function is confirmed by a prolonged beep. Refer to hold-down list:
1
- Siren Test
2
- Display Bypassed
Zones
3
- Display Troubled
Zones
4
- Delay Delete
5
- Activate Chime
6
- Tel. Programming
7
- Zone Test
8
- Code Programming
9
- Delete Last key Press
0
– Display Alarm History
*
and #
- Panic
0
Shunt
and
1
Siren
Display and Setting of System Time:
Hold down ‘0’ key
and then hold-down ‘1’, three LEDs are blinking, wait for the time to be displayed in
4-digit format.
To set new time, hold down key ‘0’ and then hold down ‘1’. Do not wait for time
display; enter the new time in 24-hour format. The local clock time is not stored in the
system memory; clock must be adjusted after power-up. After powering-up the
system, time is reset to 00:00, ‘h’ will be displayed to remind user to set time; ‘h’ will
disappear after the new time is set.
0
Shunt
and
2
Shunt
Display
Display and Setting of System Date:
Hold down ‘0’ key
and then hold-down ‘2’; 3 LEDs will blink. Enter date: ‘dd mm yy.’ The up and
download PC software displays time and date, along with history event.
*
7
4
1
0
8
5
2
#
9
6
3
Siren
Shunt
Display
Status
Delay
Delete
Chime
Test
Program
Reset
Shunt
Telephone
ARMED STATUS SHUNT
FIRE
ZONE
DISPLAY
EASYLOADER AV-701
AV-GAD
Panic Button