9. Serial Communication Commands
79
© Copyright Reserved Autonics Co., Ltd.
IHR
It reads 2Byte EEPROM data. Data is hexademical 4-digit.
Format
Command
[Axis specification]
[CR]
IHR
X EEPROM address [CR]
Y
[Example] To reads Speed Multiplier of X-axis
IHR
XE6
[Response]
IHR
X EEPROM address , Data (hexademical 4-digit) [CR]
Y
[Example] To set Speed Multiplier of X-axis=100
IHR
XE6,0064
IXS
It edits 4Byte EEPROM data. Data should be transmitted after converted to hexademical 8-digit.
Format
Command
[Axis specification]
[CR]
IXS X EEPROM address , Data (hexademical 8-digit) [CR]
Y
[Example] To set home search offset of X-axis=100
IXS X79,00000064
[Response] Same with the written data
[Example] To set Speed Multiplier of X-axis=100
IXS X79,00000064
IXR
It reads 4Byte EEPROM data. Data is hexademical 8-digit.
Format
Command
[Axis specification]
[CR]
IXR X EEPROM address [CR]
Y
[Example] To read home search offset of X-axis
IXR X79
[Response]
IXR X EEPROM address , Data (hexademical 8-digit) [CR]
Y
[Example] To set Speed Multiplier of X-axis=100
IXR X79,00000064