4. Configuration of Operation Program
37
© Copyright Reserved Autonics Co., Ltd.
4.2.4 Continuous
The continuous mode outputs drive pulses in + direction when the input signal RUN+ (6) is in ON state or in
- direction when the input signal RUN- (7) is in ON state. It outputs the drive pulse until the stop signal STOP
(11) goes to the ON state, in other words, the RUN signal of the drive is changed into the Stop signal (If the
Limit input in the proceeding direction is activated, the output stops).
The drive speed is configured as one of four drive speeds (from drive speed1 to 4) by the input signal SPD0
and 1 (8, 9). If the configuration of the drive speed is changed in driving, the speed is changed into the
changed speed at once�
Item specified
Input signal of CN3
Operation mode specification: Continuous mode MODE0 (12) = OFF, MODE1 (13) = ON
Axis specification
X (4), Y (5) = On state of the axis to execute
Drive Speed specification
SPD0 (8) to SPD1 (9)
Refer to "4.2.3 JOG" <Drive Speed configuration>.
4.2.5 Program
The program drive executes the operation program registered. The program drive is started by configuring
the following items as the input signal of Parallel I/F connector (CN3) when the drive start command, STOBE
(3) is in ON state.
Item specified
Input signal configuration to CN3
Operation mode: Index mode
MODE0 (12) = ON, MODE1 (13) = ON
Axis specification
X (4), Y (5) = ON state of the axis to execute
Register number specification
REGSL (6) to REGSL5 (11)
Refer to "4.2.2 Index" <Register number specification table> .