5. Drive by PC
47
© Copyright Reserved Autonics Co., Ltd.
5.4
Program Edit Screen
The program edit screen is used to display/edit the operation program of X or Y-axis.
The program is registered to registers from 0 to 63�
The program edit screen is consists of the program display part, the program input part and the parameter
display part� The input or edit of the program is carried out in the program input part� If you click a certain
register in the program display part, the selected register number is displayed in the REG field of the
program input part�
5.4.1 Input and edit a program
For the displayed register, input each item as shown below� Whenever you click the [Enter] button, data is
displayed at the corresponding REG of the program display part and the register number is increased by
one� In online state, the data is automatically added in the main body�
Input item
Command
Description
Command
Click (▼) to select the following commands.
ABS (move absolute position), OUT (ON/OFF of output port),
IJP (jump input condition), INC (relative position movement), NOP (no operation),
OTP (ON pulse of output port), JMP (jump), HOM (home search),
REP (start repetition), TIM (timer), RPE (end repetition), END (end program)
Data
ABS
Absolute position
INC
Relative position
OUT
Output post number - 0 (Off)/1 (On)
OTP
Output post number - ON time (0 to 65,535 msec)
IJP
Input port number - register number to jump
JMP
Register number to jump
REP
Repetition count (1 to 255)
TIM
Waiting time (0 to 65,535 msec)
Other commands
Not required to configure
Speed
ABS, INC
Selection of drive speed 1 to 4
Other commands
Not required to configure
Timer
ABS, INC
Selection of post timer 1 to 3
If it is unnecessary, select zero�
Other commands
Not required to configure
Parameter
display part
Program
display part
Program
input part