5. Drive by PC
48
© Copyright Reserved Autonics Co., Ltd.
Input item
Command
Description
End P
ABS, INC, HOM
1: Output the end pulse after running the command
0: No-output after running the command
Caution
For 1, the drive end pulse must be enabled in mode
configuration.
Other command
Relative position
Both
ABS, INC and HOM on X-axis
Output port number: 0(OFF) / 1(ON)
Other command
Output port number: ON time (0 to 65,535 msec)
●
Reset: If the [Reset] button is pressed before the [Enter] button is pressed, the input data is reset and
the previous data is displayed�
Caution After entering data, press the [Enter] button to update the program�
(1)
File menu
The File (F) menu on the Program Edit screen has Save, Open commands for the operation program.
This menu has the same function with the File menu of the main screen�
(2)
Edit menu
The Edit (E) menu of the Program Edit screen is listed as shown the table below.
Item
Function
Description
Cut
Clear of the selected area
Move the selected area to the clipboard. In online state, the program
data of the changed register is added to the main body�
Copy
Copy of the selected area Copy the selected area to the clipboard�
Paste
Paste
Paste the selected area to the current register� In online state, the
program data of the changed register is added to the main body�
Delete Deletion of lines
Delete the selected register in line unit� The register number after the
deletion can be advanced� In online state, the program data after the
deleted line is added to the main body�
Insert
Insertion of lines
Insert blanks to the selected line� If the last line number of the
program after inserting blanks is over 63 with the numbers or more
than 63 are deleted� In online state, the inserted program data is
added to the main body�