9. Serial Communication Commands
75
© Copyright Reserved Autonics Co., Ltd.
OUT
Control the output signal. The OUT controls the output signal by configures as hexadecimal.
Format
Command [Data] [CR]
OUT [CR]
Bit composition
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
(XOUT0) XOUT0
(XOUT1) XDRIVE
(XOUT2) XERROR
(XOUT3) Not used
(XOUT4) Not used
(XOUT5) Not used
(XOUT6) Not used
(XOUT7) Not used
(YOUT0) YOUT0
(YOUT1) YDRIVE
(YOUT2) YERROR
(YOUT3) Not used
(YOUT4) Not used
(YOUT5) Not used
(YOUT6) Not used
(YOUT7) Not used
RST
It resets the motion control IC�
The RST only resets the motion control IC�
Format
Command[CR]
RST[CR]
Response: No-response
SCI
It reads or modifies the condition of a communication port.
If the port condition is modified, reset of main body or power is required.
(1)For reading
Format
Command [CR]
SCI [CR]
0: OFF / 1: ON