5. Drive by PC
50
© Copyright Reserved Autonics Co., Ltd.
5.6
Error code
Errors listed in the table below are displayed at the bottom of the main screen�
Code
Error message
Description
208
SOFTWARE LIMIT + ERROR
Software LMT+ occurred.
209
SOFTWARE LIMIT - ERROR
Software LMT- occurred.
210
HARDWARE LIMIT + ERROR
nLMT+ signal is active level.
211
HARDWARE LIMIT - ERROR
nLMT- signal is active level.
212
ALARM ERROR
nALARM signal is activated by the Enable configuration.
213
EMG ERROR
EMG is low level (GEX connection).
214
PROGRAM ERROR
Program error
215
HOME ERROR
Home Search error of the main body
401
Break signal was received
The stop signal is received�
402
Frame error
Frame error
403
Port Overrun error
Port overrun
404
Recive buffer Overflow
Receive buffer overflow
405
Parity error
Parity error
406
Send buffer Full
Send buffer is full
407
Device control block of Port
was received
Unexpected error acquiring the device control block
(DCB) of a port
408
There is no response
No response for the command
501
X Axis is already driving now
X-axis was driven during the operation of X-axis
502
Y Axis is already driving now
Y-axis was driven during the operation of Y-axis
503
Please select Axis
Home Search and Index/Program was selected without
selecting any axis on the main screen�
504
Please input number from
0 to 63 for REG
A number other than 0 to 63 was inputted in REG
505
Please input number
Not specified value was input.
506
Please input number within
the limits
A value other than input range was input�
The online state can be changed into the offline state.
To recover the online state, select the File (F) and retry the communication such as Upload → Parameter →
X-axis.