8
SecuraLift® Rhino
Installation Instructions & Owner’s Manual
P.E. Beams Auto-Close Shunt
has to be placed on to enable the Auto-Close feature.
PROG INPUT
is used to connect the PG-3 Universal Handheld Programmer to edit control and receiver functions.
Terminal Block:
PWR
- Used to power devices such as P.E. Beams and external receiver (100 milliamp max).
PE
- Used to connect to P.E. Beams.
PE- -
A 0 volt connection for P.E. Beams.
COM -
A common -ve ground for accessories.
OSC
- Used for the connection of a wired switch (momentary contact). This switch can then be used to open,
stop or close the door. Install the wall switch in a location where the switch is out of reach of children
and the garage door is visible.
AUX
- Allows the opener to operate other devices such as external lights, or an alarm system.
OPEN LIMIT LED (Green)
is used during installation to set the open limit position. It also illuminates and fl ashes as
the door opens, and remains on when the open limit position has been reached.
CLOSE LIMIT LED (Red)
is used during installation to set the close limit position. It also illuminates and fl ashes as
the door closes, and remains on when the close limit position has been reached.
MINUS (-) button (Red)
is used during installation to set the close limit position. Pressing and holding this button
will move the door in the close direction. Movement stops when the button is released. This button is also used for
storing or erasing the transmitter button you wish to use to command the door to open, stop or close.
NOTE: The safety obstruction system is inoperable whenever the MINUS (-) button is used to move the door.
CODE SET LED (Red)
fl ashes when a transmitter button is stored.
LIMIT SET button (Blue)
is used during installation, together with the PLUS (+) and MINUS (-) buttons, to set the
door limit positions. The LIMIT SET button is also used to re-initialise the opener.
SERVICE LED (Yellow)
indicates when the opener requires service or repairs.
OPERATE button (Blue)
is used during installation to test the open, stop and close cycles for the opener. The
OPERATE button can also be used in lieu of a transmitter to activate the opener.,
FORCE MARGIN SET button
. The obstruction force margin is set automatically during installation. The margin
can be adjusted manually using the FORCE MARGIN SET button (White). Holding the FORCE MARGIN SET button
and pressing PLUS (+) or MINUS (-) buttons will increase or decrease the amount of force. The FORCE MARGIN SET
button should only be used if environmental factors, such as high winds, affect the door’s operation.
PLUS (+) button (Green)
is used during installation to set the open limit position. Pressing and holding this button
will move the door in the open direction. Movement stops when the button is released.
NOTE: The safety obstruction system is inoperable whenever the PLUS (+) button is used to move the door.
Close Limit Adjust Screw
is used during installation to fi ne tune the close limit position.
Open Limit Adjust Screw
is used during installation to fi ne tune the open limit position.
Operating Controls
01
02
03
04
05
06
07
08
09
10
11
12
14