![Automatic Technology SecuraLift Rhino Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/automatic-technology/securalift-rhino/securalift-rhino_installation-instructions-manual_3021681017.webp)
Installation Instructions & Owner’s Manual
SecuraLift® Rhino
17
Setting Travel Limits
NOTE:
The OPERATE button will not function until
the open and close limit positions are set.
NOTE:
If P.E. Beams is to be used it must be installed
before setting the travel limits.
Step 15.1 - Remove Controls Cover
Remove the controls cover to access the control panel
(Fig. 23). Replace it when setup is completed.
Step 15.2 - Connect Power to the Drive unit
Plug the power cord into a mains point and switch power
on. The red CLOSE LIMIT LED will be fl ashing (Fig. 24).
NOTE:
The door and shuttle must be engaged into
the chain index for the door to move.
WARNING:
The safety obstruction detection system
is inoperable while MINUS (-) and PLUS (+) drive
buttons are being used and travel limits are not set.
Step 15.3 - Set the Close Limit Position
Press and hold the MINUS (-) button (Fig. 24) until the
door reaches the desired close limit position.
Using a small screwdriver turn the red close limit
adjust screw anticlockwise (Fig. 25) until the red
CLOSE LIMIT LED illuminates (Fig. 24).
Step 15.4 - Fine Tuning the Close Limit
Position
Hold the PLUS (+) button to open the door
approximately half a metre.
Hold the MINUS (-) button to close the door.
If an adjustment is necessary turn the close limit
adjust screw as required, and repeat Steps 15.4(a) &
(b).
Otherwise, proceed to Step 15.5.
Turning the close limit screw towards (+) allows the door
to drive more in the close direction. Turning the close
limit screw toward (-) allows the door to drive less in the
close direction. (Fig. 25)
Step 15.5 - Storing the Close Limit
Press the LIMIT SET button (Fig. 24) to confi rm the close
LIMIT SET position of the door. The green OPEN LIMIT
LED should now be fl ashing.
a.
b.
a.
b.
c.
d.
24
Fig
23
Fig
25
Fig