Menu 5. Output Four Setup
The output setup parameters in Menu 5 is used to confi gure Output Four.
Menu 5.1: Output Pulse Time
This parameter sets the duration of the output pulse time. The output pulse time is used only for pulse
functions. The time is adjustable from 0.1 to 99.9 units.
Menu 5.2: Pulse Time Units
This parameter sets the units used for the output time settings. The options are Sec, Min or Hrs.
Menu 5.3: Flash On Time & Menu 3.4: Flash Off Time
A fl ash on an output is created by repeatedly turning the output on and off. The Flash On Time sets the
duration of the on phase while the Flash Off Time sets the duration of the off phase. For a steady output state
which does not fl ash, set the Flash On Time = 0.0s. The Flash Off Time is not used for steady state outputs.
Menu 5.5: Complete Flash Sequence
Turning this parameter on will allow the fl ash cycle to complete if the output is turned off during the fl ash cycle.
Menu 5.6: Output Four Inverted
Output Four is confi gured for N/O operation. This parameter allows its operation to be changed to N/C.
Menu 5.7: Trigger Four Input
Output Four can also be controlled via independent Trigger Four input. The trigger input can be programmed to
activate its output similar to a transmitter button.
Menu 5.8: Trigger Four Input Contact
Trigger Four input is confi gured for N/O operation. This parameter allows its operation to be changed to N/C.
Menu 5.9: Disable Four Input Contact
This input can be used to disable the output in software regardless of the state of the transmitters , wired
inputs or time clock. The disable input is normally confi gured for N/O operation. This parameter allows its operation
to be changed to N/C.
Menu 6 Operating Modes
Menu 6.1-4 Default Tx B1-4 Functions
These parameter are used to set the default output function offered when coding a transmitter button.
Menu 6.5 Remote Code
The receiver supports the Remote Code Set feature. This parameter can be used to disable the feature for
security or transmitter management reasons.
Menu 6.6 Activity Reports
This parameter enables activity report outputs. Contact Automatic Technology for more details.
Menu 6.7 Activity Report ID
This parameter sets the ID of the controller that is sent with the activity report. Contact Automatic Technology
for more details.
Menu 6.8 Vacation Mode
Vacation mode can be turned on or off using this parameter.
Menu 5 Output Four Setup