16
MegaCode® Receiver
Owner Installation Instructions
Menu 3.6: Output Two Inverted
Output Two is confi gured for N/O operation. This parameter allows its operation to be changed to N/C.
Menu 3.7: Trigger Two Input
Output Two can also be controlled via independent Trigger One input. The trigger input can be programmed to
activate its output similar to a transmitter button.
Menu 3.8: Trigger Two Input Contact
Trigger Two input is confi gured for N/O operation. This parameter allows its operation to be changed to N/C.
Menu 3.9: Disable Two Input Contact
This input can be used to disable the output in software regardless of the state of the transmitters , wired
inputs or time clock. The disable input is normally confi gured for N/O operation. This parameter allows its operation
to be changed to N/C.
Menu 4 Output Three Setup
Menu 4. Output Three Setup
The output setup parameters in Menu 4 is used to confi gure Output Three.
Menu 4.1: Output Pulse Time
This parameter sets the duration of the output pulse time. The output pulse time is used only for pulse
functions. The time is adjustable from 0.1 to 99.9 units.
Menu 4.2: Pulse Time Units
This parameter sets the units used for the output time settings. The options are Sec, Min or Hrs.
Menu 4.3: Flash On Time & Menu 3.4: Flash Off Time
A fl ash on an output is created by repeatedly turning the output on and off. The Flash On Time sets the
duration of the on phase while the Flash Off Time sets the duration of the off phase. For a steady output state
which does not fl ash, set the Flash On Time = 0.0s. The Flash Off Time is not used for steady state outputs.
Menu 4.5: Complete Flash Sequence
Turning this parameter on will allow the fl ash cycle to complete if the output is turned off during the fl ash cycle.
Menu 4.6: Output Three Inverted
Output Three is confi gured for N/O operation. This parameter allows its operation to be changed to N/C.
Menu 4.7: Trigger Three Input
Output Three can also be controlled via independent Trigger Three input. The trigger input can be programmed to
activate its output similar to a transmitter button.
Menu 4.8: Trigger Three Input Contact
Trigger Three input is confi gured for N/O operation. This parameter allows its operation to be changed to N/C.
Menu 4.9: Disable Three Input Contact
This input can be used to disable the output in software regardless of the state of the transmitters , wired
inputs or time clock. The disable input is normally confi gured for N/O operation. This parameter allows its operation
to be changed to N/C.