Menu 2. Output One Setup
The output setup parameters in Menu 2 is used to confi gure Output One.
Menu 2.1: Output Pulse Time
This parameter sets the duration of the output pulse time. The output pulse time is used only for pulse
functions. The time is adjustable from 0.1 to 99.9 units.
Menu 2.2: Pulse Time Units
This parameter sets the units used for the output time settings. The options are Sec, Min or Hrs.
Menu 2.3: Flash On Time & Menu 2.4: Flash Off Time
A fl ash on an output is created by repeatedly turning the output on and off. The Flash On Time sets the
duration of the on phase while the Flash Off Time sets the duration of the off phase. For a steady output state
which does not fl ash, set the Flash On Time = 0.0s. The Flash Off Time is not used for steady state outputs.
Menu 2.5: Complete Flash Sequence
Turning this parameter on will allow the fl ash cycle to complete if the output is turned off during the fl ash cycle.
Menu 2.6: Output One Inverted
Output One is confi gured for N/O operation. This parameter allows its operation to be changed to N/C.
Menu 2.7: Trigger One Input
Output One can also be controlled via independent Trigger One input. The trigger input can be programmed to
activate its output similar to a transmitter button.
Menu 2.8: Trigger One Input Contact
Trigger One input is confi gured for N/O operation. This parameter allows its operation to be changed to N/C.
Menu 2.9: Disable One Input Contact
This input can be used to disable the output in software regardless of the state of the transmitters, wired inputs
or time clock.The disable input is normally confi gured for N/O operation. This parameter allows its operation to be
changed to N/C.
Menu 3 Output Two Setup
Menu 3. Output Two Setup
The output setup parameters in Menu 3 is used to confi gure Output Two.
Menu 3.1: Output Pulse Time
This parameter sets the duration of the output pulse time. The output pulse time is used only for pulse
functions. The time is adjustable from 0.1 to 99.9 units.
Menu 3.2: Pulse Time Units
This parameter sets the units used for the output time settings. The options are Sec, Min or Hrs.
Menu 3.3: Flash On Time & Menu 3.4: Flash Off Time
A fl ash on an output is created by repeatedly turning the output on and off. The Flash On Time sets the
duration of the on phase while the Flash Off Time sets the duration of the off phase. For a steady output state
which does not fl ash, set the Flash On Time = 0.0s. The Flash Off Time is not used for steady state outputs.
Menu 3.5: Complete Flash Sequence
Turning this parameter on will allow the fl ash cycle to complete if the output is turned off during the fl ash cycle.
Menu 2 Output One Setup