INSTRUCTIONS CABRI-20P
Page 24
SWING GATE OPENER
4.2.3
Electric Latch Adjustment (Dip 5.Latch)
ON: The master leaf will move toward closing direction for 0.25 second once
command the remote, then unlock the latch to open the gate.
OFF: Once command the remote, the the latch will be unlocked to open the gate
immediately
4.2.4 Decelaration Speed Adjustment of the Gear Motors (Dip 6. D Speed
)
ON: The speed is70% output of the full speed.
OFF: The speed is 50% output of the full speed.
4.2.5 Operation Speed Adjustment of the Gear Motors (Dip 7.O Speed)
ON: The speed is 100% output of the full speed.
OFF: The speed is 70% output of the full speed
.
4.2.6
Single and Dual Gate Operation Adjustment (Dip 8.Ds/set)
ON: Dual Gates operation in system learning and normal operation.
OFF: Single Gate operation in system learning and normal operation
.
4.3 LED Indication
LED1 System Learning:
LED1 is always ON when the system learning in not
completed.
LED1 blinks once when single-gate learning is completed ;
LED1 blinks twice when dual-gate learning is completed.
LED 2 RF :
If the switch of the transmitter, key selector, or the push button is
activated, LED2 will be on.
LED 3 Photocells 1 :
LED3 will be on when the first pair of the photocells are
activated.
LED 4 Photocells 2
: LED4 will be on when the second pair of the photocells are
activated.
LED 5 RF Indicator :
LED5 will be on when RF signal is received.