INSTRUCTIONS CABRI-20P
Page 19
SWING GATE OPENER
5. Wiring Connection:
Prepare all the wires of the accessories beforehand and connect the wires to the
gear motors and accessories on the PCB as shown in Figure 1(4). All of the wiring
connections of the accessories are not requested to
distinguish the positive (+) and
the negative (-) polarity.
1). Flashing light: Connect the two wires from the flashing light to the terminal
L+ and L- on the PCB.
2). Electric Latch: Connect the two wires from the electric latch to the terminal
Lo + and Lo- on the PCB.
3). Gate openers: Refer to Figure 1(4) and connect the wires separately to the
terminals on the PCB.
Motor 1:
Connect the motor wire (White +) to the terminals Mo1 +, and
(Yellow -) to the Mo1-.
Motor 2:
Connect the motor wire (White +) to the terminals Mo2 +, and
(Yellow -) to the Mo2 -.
Notes:
For gates opened outward.
Motor 1:
Connect the motor wire (Yellow -) to the terminals Mo1 +, and
(White +) to the terminals Mo1-.
Motor 2:
Connect the motor wire (Yellow -) to the terminals Mo2 +, and
(White +) to the terminals Mo2
-.
4). Photocells: See Figure 1(4)
(A) installed one set Photocell to FO1, SW3 setting as below:
3. Ph_conn1 > OFF and 4. Ph_conn2 > ON
(B) installed one set Photocell to FO2, SW3 setting as below:
3. Ph_conn1 > ON and 4. Ph_conn2 > OFF
(C) installed two sets Photocell, SW3 setting as below:
3. Ph_conn1 > OFF and 4. Ph_conn2 > OFF
(D) No Photocell has been installed, SW3 setting as below:
3. Ph_conn1 > ON and 4. Ph_conn2 > ON