INSTRUCTIONS CABRI-20P
Page 14
SWING GATE OPENER
2.3.3 Flashing Light
1) Decide the installation position of the flashing light. The flashing light has to be
installed near the gate and easy to be seen by users and passersby. The flashing
light can be installed horizontally or vertically.
Figure 2.3.3 (1).
2) Unscrew the four screws on the light base and separate the base with the bottom
as shown in
Figure 2.3.3 (2).
3) Connect the wires and penetrate the wires into the hole of the base.
Figure 2.3.3 (3).
4) Drill the holes in the wall and fix the bottom to the wall by three screws.
Figure 2.3.3 (4)
Figure 2.3.3(1) Figure 2.3.3(2) Figure 2.3.3(3) Figure 2.3.3(4)
5). Connect the two wires of the light to the PCB terminals and place the wires into the
conduit if necessary. See Figure 2.3.3 (5).
6). Tighten the four screws back on the light base. Figure 2.3.3 (6)
7). Replacing the bulb set. See Figure 2.3.3 (7)
7.1) Unscrew the flashing light wires from the PCB terminals and make sure the
power of the light is off.
7.2) Release the three screws (A) (B) (C) of the flashing light cover.
7.3) Separate the flashing light cover and replace the bulb set with a new one.
7.4) Tighten the three screws (A) (B) (C) of the flashing light cover.
Figure 2.3.3(5) Figure 2.3.3(6) Figure 2.3.3(7)