INSTRUCTIONS CABRI-20P
Page 22
SWING GATE OPENER
4.1.3 Gate Auto close Adjustment
(Dip 4. Auto C1, Dip 5. Auto C2 & Dip 6. Auto C3)
Auto C1 Auto C2 Auto C3
Effect
Dip switch 4 OFF
Dip Switch 5 OFF
Dip Switch 6 OFF
No auto-close
Dip switch 4 OFF
Dip Switch 5 OFF
Dip Switch 6 ON
3 sec.
Dip switch 4 OFF
Dip Switch 5 ON
Dip Switch 6 OFF
10 sec.
Dip switch 4 OFF
Dip Switch 5 ON
Dip Switch 6 ON
20 sec.
Dip switch 4 ON
Dip Switch 5 OFF
Dip Switch 6 OFF
40 sec.
Dip switch 4 ON
Dip Switch 5 OFF
Dip Switch 6 ON
60 sec.
Dip switch 4 ON
Dip Switch 5 ON
Dip Switch 6 OFF
120 sec.
Dip switch 4 ON
Dip Switch 5 ON
Dip Switch 6 ON
360 sec.
Note : Auto-Close mode activates when the gates move to the end position or stopped
manually. If the transmitter or push button is activated before the auto-close counting, the
gate will close immediately.
4.1.4 Pedestrian Mode Adjustment (Dip 7.P Mode)
ON: Press button B on the remote to operate to pedestrian mode by open single gate to
45 degree
OFF: The pedestrian mode is disabled. Single gate will fully open and close
.
4.1.5 Flashing Light Adjustment (Dip 8.Light)
ON: The flashing light blinks for 3 seconds before the gate moves, and blinks
simultaneously during the movement.
OFF: The flashing light blinks and the gate moves simultaneously.
4.2 Sw2 Dip Switch Setting
4.2.1 Photocell Adjustment (Dip 1.Photo1, Dip 2.Photo2)
1. SW2_2, SW2_1: OFF OFF
Position of Gate When safety devices are activated
Type of Safety Device
Safety Device2:
Photocell-OPEN
Safety Device1 :
Photocell-CLOSE
FULLY CLOSED
Open not allowed
No effect
FULLY OPENED
No effect
Reload automatic closing time
STOP DURING MOVING
Open not allowed
Reload automatic closing time
CLOSING
No effect
Open
OPENING
Close
No effect