Assembly Instruction
KS2 / KS2 T
WIN
I
NSTALLATION
STEP
5:
H
OLE
LAYOUT
FOR
FRAME
AND
CASEMENT
BRACKETS
05
Tandem application KS2 xxx / Combination right / left
(Bottom-hung - inward opening windows)
24V
H
OLE
LAYOUT
FOR
THE
FRAME
BRACKETS
K94 / K129
AND
CASEMENT
BRACKET
F21 (
DRIVE
AT
SIDE
)
I
NSTALLATION
STEP
5
L
:
24V
K129 = 36
K94 = 24
AK
X
FAH min.:
min.
strok
e
AK
BD
RA
FL
B
A
A
F21
K94
M5x10
DIN 7500
A
F21
K129
M5x10
DIN 7500
FAB = max. 1200
section:
see below
From FAB > 1200 mm is a
locking drive required!
C
K94
K129
F21
Window
Stroke
A
B
C
X
Max.
opening
200
336 350 170,5
≥ 380
60
300
381 395 215,5 ≥ 470
60
400
431 445 265,5 ≥ 570
60
500
546 560 380,5 ≥ 800
60
600
546 560 380,5 ≥ 800
60
800
626 640 460,5 ≥ 960
60
• only for bottom-hung casements
(inward opening windows)
• respect max. pulling forces of drives.
• cable exit (power supply) on top.
• rigid-backed side of chain upward.
• white wires must be connected.