Assembly Instruction
KS2 / KS2 T
WIN
I
NSTALLATION
STEP
5:
H
OLE
LAYOUT
FOR
FRAME
AND
CASEMENT
BRACKETS
05
Solo application KS2 xxx / Version: right
Tensile load - Frame assembly
(Bottom-hung - outward opening windows)
230V
(Bottom-hung - outward opening windows)
24V
230V
Stroke 200 Stroke 300 Stroke 400 Stroke 500 Stroke 600 Stroke 800
A
476
521
571
686
686
766
B
490
535
585
700
700
780
C
170,5
215,5
265,5
380,5
380,5
460,5
X
≥ 570
≥ 570
≥ 570
≥ 800
≥ 800
≥ 960
Y
≥ 475
≥ 520
≥ 570
≥ 685
≥ 685
≥ 765
Minimum overall height of casement
(FAH)
Stroke 200 300 400 500 600 800
Height
325 450 550 675 800 1080
Frame bracket:
Casement bracket:
Drive:
Space on the frame: 22 mm
K94
F21
fi xed
K94
A
M5x10
DIN 7500
F21
K94 = 24
K94
AK
1/2 FAB
F21
RA
FL
B
C
A
X
Y
= Symmetrical /
= Asymmetrical
FAB min.:
When mounting two drives (tandem operation),
a minimum distance of 50 mm between the drives
is considered.
Window versions:
Version left (L):
as right (R), but in mirror image
Bottom hung - outward opening
Top hung - outward opening
Side-hung - outward opening
Horizontally pivoting casement
Projecting top-hung
casement
Version: left