Assembly Instruction
KS2 / KS2 T
WIN
M-COM (Main control unit)
Order number:
Application:
Rated voltage:
Current consumption:
Drive type:
Protection class:
Ambient temperature:
Dimensions:
Connecting wires:
524177
Main control unit for the automatic
confi guration and monitoring of max. 4
opening / 2 locking drives type S12 / S3
(software version SW-V2) in multi-drive
systems.
24V DC +/- 20%, (max. 2 Vss)
<12 mA
S12
IP30 rubber jacket
0 °C ... + 70 °C
45 x 17 x 6 mm
3 wires 0,5 mm² x 50 mm
Feature / Equipment:
printed circuit board with
connecting wires for in-
tegration in site-supplied
junction box.
I
NSTALLATION
STEP
9:
E
LECTRIC
CONNECTION
E
LECTRIC
CONNETCTION
Multi-drive operation with M-COM
WH is used for communication,
with synchronized multi-drive operation.
from control unit
drive 1
drive 2
BN
BU
24V DC control
WH
AK
AK
junction box
site-supplied
Connection
no synchronous running , if not connected
M-COM
24V
24V
Optional: 1 to 4 drives (at KS2 Twin 1 or 2 drives)
and max. 2 locking drives are possible.
UniPC with
confi guration interface
Order number:
Application:
Rated voltage.
Parameterizable
drives:
Scope of delivery:
524178
Hard- and software for confi guration of
drives supplied by
Aumüller Aumatic GmbH
24V DC +/-20%
24V DC type MP, S3, S12, S12 V.2
230V AC type S12, S12 V.2
software UniPC (Downloadlink*), Interface
“ParInt”, USB cable, connection cable
* http://www.aumueller-gmbh.de/Downloads
Features /
Equipment:
Power supply 24V DC
is not included in the
scope of delivery!
Any extended settings
require a software
licence.
Any reconfi guration of a drive is entirely at the
user‘s own risk and responsibility.
Cable junction box
(for renewal)
Order number:
Application:
Rated voltage:
Material:
Protection class:
Dimensions:
Equipment:
513344
to extend a drive cable
only for low voltage
to max. 50V DC/AC
stainless steel (V2A)
IP 40
25 x 27 x 150 mm
with cable gland PG9 (grey)
including strain relief,
with loose ceramic terminals.
For multiple operation of
the application is possible
only with the master and
slave.
(without M-COM)
24V
230V
24V
07
230V
24V
polarity
reversal